background image

9

Precautions when using the LED fixture and E-series adapter

 Warning!

 Always wait 20 - 30 minutes for the LED fixture to cool down!

Inspection, maintenance and repair

   Warning!

 Disconnect the LED fixture from mains before performing any maintenance or repairs. 

   Warning!

 Do not connect or disconnect the LED fixture under load. 

   Warning!

 Do not open or disassemble the LED fixture or E-series adapter, they contain no serviceable parts inside. Opening 

the LED fixture or E-series adapter can be dangerous and will void the warranty. 

   Warning!

 Always allow for a cool down period of at least 30 minutes before touching the LED fixture.

  Caution!

 Do not clean the LED fixture with detergents, abrasives or other aggressive substances. 

Regularly check the LED fixture for dust or dirt buildup. Clean if necessary. Contamination may cause overheating and

decreased performance. Clean the outside of the LED fixture using a dry or damp cloth.

Regularly check the cables of the LED fixture to ensure it is undamaged.

9.1 

How to disconnect the Wieland RST16i5 plug

   Warning!

 Do not connect or disconnect the Wieland RST16i5 plug under load. 

Switch off mains power.

Turn the ring on the Wieland RST16i5 female connector counterclockwise and pull the

Wieland RST16i5 female connection from the LED fixture (fig. 15).

10 

Storage and disposal

Store the LED fixture in a dry and clean environment, with an ambient temperature of

-20~85° C.

The product must not be discarded as unsorted municipal waste, but must be collected

separately for the purpose of treatment, recovery and environmentally sound disposal.

11 

Warranty service

Gavita International b.v. warrants the mechanical and electronic components of their product to be free of defects in material 

and workmanship if used under normal operating conditions for a period of 

five

 (

5

) years from the original date of purchase. If 

the product shows any defects within this period and that defect is not due to user error or improper use Gavita International 

b.v. shall, at its discretion, either replace or repair the product using suitable new or reconditioned products or parts. In case

 

Gavita International b.v. decides to replace the entire product, this limited warranty shall apply to the replacement product

 

for 

the remaining initial warranty period, i.e. 

five

 (

5

) years from the date of purchase of the original product. For service

 

return the 

Gavita Pro 1700

e

 LED fixture to your shop with the original sales receipt. 

PLEASE NOTE: greater than 15% of the

 

diodes must be 

non-functional before the unit can be considered defective.

1

2

12.

Summary of Contents for Pro 1700 LED EU 240

Page 1: ...roduct may not be discarded as household waste By properly disposing the equipment you will be helping to prevent possible risks to the environment and public health which might otherwise be caused by improper handling of the discarded equipment Recycling of materials contributes to the conservation of natural resources Therefore please do not dispose of old electronics and electrical appliances v...

Page 2: ... 5 meter PC6852002 Gavita Power cord ESA CH 2 5 meter PC6852001 Gavita Power cord ESA AUS 2 5 meter PC6852005 Interconnect cables Gavita Interconnect cable ESA RJ45 RJ45 10 ft 3 0m HGC906711 Gavita Controller cable ESA RJ45 RJ9 25 ft 7 5m HGC906717 Gavita Controller cable ESA RJ45 RJ9 10 ft 3 0m HGC906716 Gavita 3 way splitter ESA 1f to 2f RJ45 HGC906721 Sun Grips Sun Grip Original Light Hanger 1 ...

Page 3: ...atures outside the specified range dust and contamination direct sunlight during use or HID light that could heat up the ballast Always disconnect the LED fixture from mains before performing any maintenance Always allow for a cool down period of at least 30 minutes before touching the LED rails Touching the LED rails when the fixture is lit or immediately afterwards can result in severe burns Do ...

Page 4: ...s B Distribute the fixture weight evenly so fixture hangs level fig 3 Sun Grip light hangers allow the LED fixture to easily move upwards and downwards fig 4 according to your crop height fig 5 Make sure power cords 1 Are not concealed or extended through a wall floor ceiling or other parts of the building structures 2 Are not located above a suspended ceiling or dropped ceiling 3 Are not permanen...

Page 5: ...re If you use the LED fixture stand alone connect the Wieland RST 16i5 female connector on the power cable to the Wieland RST16i5 male connector on the LED fixture fig 13 If you use the LED fixture with a Master Controller connect the Wieland RST16i5 female connector on an E series adapter not included to the Wieland RST16i5 male connector on the LED fixture fig 14 Connect the power cable to the m...

Page 6: ...i5 male connector B Gavita 2xRJ connector 1 RJ IN 2 RJ OUT 7 2 Contents of the repeater bus connection kit Not included sold separately The E series adapter interconnect kit contains the following items C 80ft interconnect cable D RJ45 3x RJ14 terminal connectors 3x OPTIONAL Interconnect cable 3 way splitter Interconnect cable crimper Crimp tool 7 3 Preparation for use with a controller Using a da...

Page 7: ... to connect the controller input port on the first E series adapter fig 10A Remove the dummy from the input port on the second E series adapter Use interconnect cable RJ45 RJ45 to connect the output port of the first E series adapter to the input port of the second E series adapter fig 10B Repeat these steps to connect up to 100 E series adapters fig 10C Warning Ensure the power cord and the contr...

Page 8: ...port of the second fig 12D Repeat these steps to connect up to 100 E series adapters per splitter output port fig 12E Up to 500 E series adapters can be connected to the primary channel Use RJ45 RJ45 modular jack interconnect cables item C to connect the outport of a splitter to the input port of the next splitter fig 12F Use the secondary channel fig 12G to connect another 500 E series adapters i...

Page 9: ...i5 female connector counterclockwise and pull the Wieland RST16i5 female connection from the LED fixture fig 15 10 Storage and disposal Store the LED fixture in a dry and clean environment with an ambient temperature of 20 85 C The product must not be discarded as unsorted municipal waste but must be collected separately for the purpose of treatment recovery and environmentally sound disposal 11 W...

Page 10: ...e LED EU Changes reserved Version 20 18 Not for sale or use in the Netherlands GAVITA International bv Oosteinderweg 127 1432 AH Aalsmeer The Netherlands Tel 31 0 297 380 450 Fax 31 0 297 380 451 E info gavita com W www gavita com ...

Reviews: