8
7.5
Connecting up to 500 or 1000 E-series adapters
Using a setup with daisy chained splitters, up to 500 E-series adapters on EL1 and 1000 E-series adapters on EL2 (over two
channels) can be connected as shown in fig. 12.
•
Use the controller cable (RJ45 - RJ9) to connect the primary channel of the controller to the input port of the first splitter
(fig. 12A).
•
Remove the dummy from the input port of the E-series adapter (fig. 10).
Note: Keep the dummy in a safe place!
The dummy is necessary to operate the E-series adapter in standalone mode.
•
Use a RJ45 - RJ45 modular jack interconnect cable (item C) to connect the output port of the splitter to the input port of
the first E-series adapter (fig. 12C).
•
Use a RJ45 - RJ45 modular jack interconnect cable (item C) to connect the output port of the first E-series adapter to the
input port of the second (fig. 12D).
•
Repeat these steps to connect up to 100 E-series adapters per splitter output port (fig. 12E). Up to 500 E-series adapters can
be connected to the primary channel.
•
Use RJ45 - RJ45 modular jack interconnect cables (item C) to connect the outport of a splitter to the input port of the next
splitter (fig. 12F).
•
Use the secondary channel (fig. 12G) to connect another 500 E-series adapters in the same way the E-series adapters are
connected to the primary channel.
Warning!
Ensure the power cord and the controller cables do not touch the E-series adapters.
Warning!
Distribute number of E-series adapters evenly over daisy chains.
Warning!
Ensure the repeater bus connections are integrated in a correctly set up installation for best results.
Warning!
Boosters should never be used to expand.
Warning!
The maximum cable length per splitter is 250m (100 interconnect cables).
1
2
100
101
102
200
201
202
300
401
402
500
F
301
302
400
501 - 1000
B
A
G
1700e
LED
FIXTURE
1700e
LED
FIXTURE
1700e
LED
FIXTURE
D
E
C
11.