background image

13

Pro

 line

Pro

 line

11  

Storage and disposal

• 

Store the luminaire in a dry and clean environment, with an ambient temperature of -20 ~ 85 °Celsius.

• 

The product must not be discarded as unsorted municipal waste, but must be collected separately for the purpose of 
treatment, recovery and environmentally sound disposal.

 

1

Caution!

 The lamps are chemical hazardous waste and must be delivered to the designated authorities.

 

1

Caution!

 The lamp contains mercury.

12  

Warranty

Gavita International bv warrants the mechanical and electronic components of their product to be free of defects in 
material and workmanship if used under normal operating conditions for a period of three (3) years from the original date 
of purchase. If the product shows any defects within this period and that defect is not due to user error or improper use 
Gavita International bv shall, at its discretion, either replace or repair the product using suitable new or reconditioned 
products or parts. For HPS lamps the warranty period is one (1) year from the original date of purchase. In case Gavita 
International bv decides to replace the entire product, this limited warranty shall apply to the replacement product for the 
remaining initial warranty period, i.e. three (3) years from the date of purchase of the original product. For service, return 
the luminaire to your shop with the original sales receipt.

Summary of Contents for Pro 1000e

Page 1: ...possible risks to the environment and public health which might otherwise be caused by improper handling of the discarded equipment Recycling of materials contributes tot the conservation of natural resources Therefore please do not dispose of your old electronics and electrical appliances via household waste A B This symbol indicates the minimum distance B between the luminaire A and the lit surf...

Page 2: ...on Gavita Pro 1000e 380 400V DE EU Product weight 3 8 kg Dimensions L W H 56 5 x 24 5 x 19 5 cm Temperature case 70 Celsius Temperature ambient 0 35 Celsius Input voltage 380 400 V AC 10 8 Input current typical 2 8 2 7 Amps Input power typical 1050 Watt Power factor 0 98 Total Harmonic Distortion 10 Frequency 50 60 Hz Certification EN 60598 1 EN 55015 2015 Insulation Class 1 requires an earth conn...

Page 3: ... no servicable parts inside Opening the luminaire can be dangerous and will void the warranty This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0 45 30 MHz Do not use the luminaire when either its lamp or its power cord are damaged Replace the pow...

Page 4: ...lectronic ballast 2 Lamp bracket 3 Lever to unlatch reflector 4 Lamp sockets 5 Reflector Gavita HR96 DE 6 Mounting points The reflector is delivery dependent it may differ from the image B Gavita Pro Plus 1000W EL DE C Interconnect cable 6PC6 modular jack delivered separately D Dummy E Wieland RST20i3 female connector with open end cable delivered separately A6 A1 A6 B A3 A5 A4 A2 C C C D C E 1 Ga...

Page 5: ...ixture see paragraph 10 2 4 If not pre installed screw the mounting point into the luminaire 5 7 2 Installing the luminaire 1 Mount the suspension bracket according to the light distribution plan 2 Hang the fixture by its two mounting points onto the suspension bracket 4 The two mounting points are spaced 30 32 cm apart 1 Caution Always hang the fixture horizontally If necessary adjustments can be...

Page 6: ...ontroller to connect the controller input port on the first luminaire 10A 3 Remove the dummy from the input port on the second luminaire 4 Use a grey 6P6C modular jack interconnect cable item C with integrated ferrite cores to connect the output port of the first luminaire to the input port of the second luminaire 10B The indicator light will blink when the connection is successful 5 Repeat these ...

Page 7: ...f a splitter to the inport of the next 11B 8 Use the black secondary channel item comes with controller 10G to connect another 500 luminaires in the same way the luminaires are connected to the primary channel 6 Warning Ensure the power cord and the controller cables do not touch any of the reflectors 6 Warning Distribute number of luminaires evenly over daisy chains 6 Warning Ensure the repeater ...

Page 8: ...the luminaire 1 Plug the Wieland RST20i3 female connection onto the Wieland RST20i3 male connection on the luminair 12 2 Switch on mains power 6 Warning Do not connect or disconnect the Wieland RST20i3 plug under load To install a new power cord 1 Remove the top part of Wieland RST 20i3 female connector from the bottom part 13 2 Pull the mains cable through the bottom part 14 3 Strip the wiring 15...

Page 9: ...ED signals are represented by colored dots All operating modes include GREEN All warning codes include RED All history codes except the ignition code include ORANGE WARNINGS and history codes overrule operating mode display 9 1 Status indications Status LED message Status luminaire Description Action Solution No power off The luminaire is not connected to the mains or the power is off Check power ...

Page 10: ...nside Opening the luminaire can be dangerous and will void the warranty 6 Warning Always allow for a cool down period of at least 30 minutes before touching the lamp or reflector 1 Caution Do not clean the luminaire with detergents abrasives or other agressive substances 1 Caution Do not touch the inside of the reflector during installation and do not use water abrasives or detergents to clean it ...

Page 11: ... hours whichever one comes first 1 Switch off mains power 2 Hold the lamp with a fabric glove to prevent it from falling Use a protective glove if the lamp is damaged 3 Open the lamp holders by sliding them outwards 19 4 Carefully take the lamp out of the luminaire 20 5 Install the new lamp with the getter near the ballast 21 with the glass vacuum seal pointed downwards Philips lamps or sideways G...

Page 12: ...The reflector is delivery dependent it may differ from the image 1 Switch off mains power 2 Remove the lamp from the luminaire see paragraph 10 2 3 Support the reflector on the side of the reflector lever to prevent it from falling 23 4 Move the reflector lever up to retract the two pins holding the reflector in place 24 5 Remove the reflector 25 6 Place the new reflector Ensure the reflector leve...

Page 13: ...erial and workmanship if used under normal operating conditions for a period of three 3 years from the original date of purchase If the product shows any defects within this period and that defect is not due to user error or improper use Gavita International bv shall at its discretion either replace or repair the product using suitable new or reconditioned products or parts For HPS lamps the warra...

Page 14: ......

Page 15: ......

Page 16: ...eg 8 1437 EL Rozenburg NH The Netherlands T 31 0 297 380 450 F 31 0 297 380 451 info gavita com www gavita com Pro line Pro line Manual Gavita Pro 1000e 380 400V Changes reserved Version 21 11 Not for sales or use in the Netherlands ...

Reviews: