CPR SUSIE®
|
User Guide
Working with the Simulator | 19
4. WORKING WITH THE SIMULATOR
4.1 OPTHALMOLOGIC EXERCISES
The eyes open when the simulator is in an
upright position and close in a supine position
. The eyes permit the following exercises:
•
Administration of orbital medicines
into the conjunctival sac
•
Removal of foreign bodies
•
Eye irrigation
Intubation
•
The simulator's airway can be intubated through
the left nasal opening, the trachea and the
mouth using LMA or endotracheal tubes.
•
Lubricate the tools with mineral oil before
using them in exercises to ensure easy
insertion and avoid damage to the simulator.
4.2 AIRWAY
4.3 RECOMMENDED DEVICE SIZES
Procedure
Recommended Device Size
Intubation (Blade size) Miller4 or MAC 3.5
LMA
Size 4
Nasal Intubation
8 mm outer diameter max
Oral Intubation
ETT 7.0 or 7.5 (no cuff)