Instructions for PY1200AC/PY1800AC/PY2500AC
28
Connecting Infrared Photocells
The below steps must be completed by a licensed electrician.
Highly recommend the use of infrared photocells as an additional safety feature.
While closing, if the ray of the Infrared Photocell is blocked, the gate will stop and reverse
immediately, to protect user and property security. To install photocells, connect wiring as
per Figure 25. You must remove the wire jumper between GND and LR on X5 terminal
(refer to Figure 26).
The distance between photocell receiver and photocell transmitter should not be less than 2
meters; otherwise, the induction effect of photocell may be affected.
Photocell
Transmitter
Figure 25
2 Core Cable
Photocell
Receiver
3 Core Cable