background image

Instruction for GT800ACL/GT1000ACL/GT1500ACL/GT2000ACL

www.gatexpertstore.com

8

Please Note: the rubber grommet must be fitted back onto the motor cover once the

cover has been re-fitted/replaced onto the base of the motor.

Step 4 - Motor Pad Footing

·

The motor pad concrete footing requires an area of no less than 500mm long x 400mm wide
and a minimum depth of 250mm (Standard requirement).

·

Ensure surface is level and parallel to the driveway.

Mounting Base Dimensions

Figure 9

Step 5 - Fitting Mounting Base and Motor

·

Fit anchor bolts(included in kit) or expansion bolts(should be prepared by users) according to

holes in mounting base (as per Figure 9).

·

Position the mounting base and fix it as per Figure 10.

·

Bolt motor to its base using the M10x50 bolts with spring and flat washers provided and tighten

as required.

Figure 10

Summary of Contents for GT800ACL

Page 1: ...www gatexpertstore com Sliding Gate Opener User Manual GT800ACL GT1000ACL GT1500ACL GT2000ACL Website www gatexpertstore com E mail sales gatexpertstore com...

Page 2: ...ate operation When mounting and positioning this product please ensure the power cable is unplugged The motor cover will need to be removed to mount the motor to the mounting plate or directly to the...

Page 3: ...e for free or replace for free 4 The malfunction and damages caused by incorrect use or man fault is not covered by this warranty CONTACT US E mail sales gatexpertstore com Please fill in the order in...

Page 4: ...Step 6 Sprocket and Chain Motor Alignment 10 Step 7 Limit Switch Stops 11 Step 8 Powering on 13 Step 9 Testing Travel and Limit Stops 14 A Intelligent Control Board 15 Programming and Wiring 15 DIP Sw...

Page 5: ...t rotates to the opposite direction This will give you an understanding of the way how the opener moves the gate Figure 2 Note Ensure that the gate opener is unplugged before proceeding with installat...

Page 6: ...ns and prevent injury to person or damage to property Instruct all users about the control systems provided and the manual opening operation in case of emergency Ensure that the power cable is connect...

Page 7: ...icture Name Quantity 1 Motor 1 2 Manual Release Keys 2 3 Remote Controls 2 4 Mounting Accessories Box 1 4 1 Sprocket Cover 1 4 2 Chain Including 2 Chain Links 6m 4 3 Tie Rod 2 4 4 Square Screw 4 4 5 R...

Page 8: ...ring Washers 10 2 4 11 Inner Hexagon Head Bolt M6X20 4 4 12 Hexagon Head Bolt M10X50 4 4 13 Nut M6 20 Nut M8 4 Nut M10 12 4 14 Flat Washer 6 20 Flat Washer 8 4 Flat Washer 10 12 4 15 Spring Washers 6...

Page 9: ...rking Noise 60dB Working Duty S2 20min Recording of up Remote Controls Standard control board 25 Intelligent control board 40 Remote Frequency 433 92 MHz Working Temperature 20 C 70 C Package Weight 2...

Page 10: ...r cable is not plugged in at any stage before Step 8 Step 1 Gate Preparation Ensure that the sliding gate is correctly installed The gate is horizontal and level and the gate can glide back and forth...

Page 11: ...and Figure 6 Figure 6 Step 3 Removing Installing Motor Cover Unscrew the two cover screws located at each side of the motor cover Remove the rubber grommet below the limit switch Figure 7 Figure 7 Spr...

Page 12: ...an 500mm long x 400mm wide and a minimum depth of 250mm Standard requirement Ensure surface is level and parallel to the driveway Mounting Base Dimensions Figure 9 Step 5 Fitting Mounting Base and Mot...

Page 13: ...motor output sprocket and chain are correctly aligned Sprocket and chain should be centered as much as possible Take the motor away from mounting base Leave a space of 30cm from the motor to end of t...

Page 14: ...der no circumstances should the gate opener output sprocket carry any weight of the gate It is the task of the gate castors or wheels to carry the weight of the gate If the gate doesn t slide freely b...

Page 15: ...top moving It is extremely dangerous that without or incorrect installation of the limit switch stops can cause crash of gate damage of internal structure of the motor moreover the gate may slide off...

Page 16: ...top catch when setting the open position under power Fit limit switch stop onto the top of chain at the point where it meets the magnetic limit switch on the motor Tighten locking screws of limit swit...

Page 17: ...uter cover has been fitted and fastened back onto the motor base Before powering up the gate opener make sure the gate can travel by hand in manual mode key unlocked Slide the gate to between the midd...

Page 18: ...or the gate frame is 10 15mm from closed gate end catch Testing the Open Position Press remote the sliding gate will begin to open The limit switch stop will hit the limit switch and the sliding gate...

Page 19: ...sor J3 Terminal Dip Switches Learn Button Potentiometers A Intelligent Control Board Programming and Wiring Any works to the 110V AC must only be performed by a licensed electrician Ensure power is of...

Page 20: ...ers 3 Automatic Close Time Setting Automatic close time setting the gate is operated to open by remote control operation and will close automatically after a few seconds delay 3 OFF 4 ON automatic clo...

Page 21: ...eft enabled Dip switch 5 is at the OFF position Do not turn Dip switch 5 to the ON position VR2 Brake Force Adjustment For adjusting brake force at the limit position during gate opening and closing T...

Page 22: ...ush Button Repeated Open Stop Close Terminal 4 Common Terminal for All External Control Push Button Terminal 3 External Stop Push Button Switch Terminal 2 External Open Push Button Switch Terminal 1 E...

Page 23: ...moving direction MOT2 Motor Terminal swap with MOT1 to change gate moving direction MOTCOM Motor Common Terminal LAMP L N Connection for warning lamp PE Motor and warning lamp earth Note If require to...

Page 24: ...ghly recommend the use of infrared photocells as an additional safety feature While closing if the ray of the Infrared Photocell is blocked the gate will stop and reverse immediately to protect user a...

Page 25: ...te Control Figure 21 Remote Control Learning Remove motor outer cover and continue to remove the transparent PCB cover press the button S1 on the control board until the LEARN indicator light turns on...

Page 26: ...ol Board Programming and Wiring Any works to the 110V AC must only be performed by a licensed electrician Ensure power is off before any modifications are made Fuse 10A 250V fuse Dip Switches LEARN Bu...

Page 27: ...OFF Single button switch CLS and COM on X4 Terminal can be used to circularly control OPEN STOP CLOSE STOP of the gate opener 2 Automatic Close Time Automatic close time setting the gate is operated t...

Page 28: ...mit Switch and Photocell Switch Additional accessories sold separately 24VDC Positive Power Supply for Accessories 24VDC GND Negative Power Supply for Accessories GND LR Photocell Input N C If no phot...

Page 29: ...ow green wire X2 Terminal PE Earth V Common Terminal of Motor U Motor Terminal Switch SW1 will change gate moving direction W Motor Terminal Switch SW1 will change gate moving direction Note If requir...

Page 30: ...nfrared Photocell is blocked the gate will stop and reverse immediately to protect user and property security To install photocells connect wiring as per Figure 24 You must remove the wire jumper betw...

Page 31: ...cularly on the remote control Single Button Mode Remote Control Figure 26 Remote Control Learning Remove the motor outer cover and continue to remove the transparent PCB cover press the button AN1 on...

Page 32: ...on AN1 when the LED2 turns off all previously paired remote controls will be deleted Maintenance The gate should be checked every month to make sure it operates normally For the sake of safety each ga...

Page 33: ...l please ensure the wiring is correct and the photocell status is N C 2 Ensure that the photocell mounting position can be mutually aligned 3 Remove the obstacle 4 Reduce the sensitivity of obstacle 5...

Page 34: ...Instruction for GT800ACL GT1000ACL GT1500ACL GT2000ACL www gatexpertstore com 30 Drawing and Measurements Figure 27...

Reviews: