Instructions for GT1000DCL
www.gatexpertstore.com
Terminal Instructions
All changes to these settings below must be completed by licensed electrician.
Note: If require to change the moving direction, 1 simple way is to change the DIP 5,
another way is changing the wires, to do so, not only MOT1 and MOT2 wires need to
be swapped
,
but also the wires of OP and CL on J10 Terminal have to be swapped
with each other.
J8 Terminal: (as per Figure 17):
Terminal ALM+:
Alarm Lamp +24VDC
Terminal ALM-:
Alarm Lamp -24VDC
J1 Terminal:
Terminal 5:
Common Terminal for Photocell
Terminal 6:
Photocell Input (N.C.).
If no photocell is fitted, use
a jumper between terminals 5 & 6.
Terminal 7:
Additional Acces24VDC
Additional accessories sold separately
J4 Terminal:
Motor Wire(above terminal connect to red motor wire, below
terminal connect to black motor wire)