GA600AC Sliding Gate Opener User Manual
28
Maintenance
The gate should be checked every month to make sure it operates normally.
For the sake of safety, each gate is suggested to be equipped with infrared protector, and
regular inspection is required.
Before installation and operation of the gate opener, please read all instructions carefully.
Our company keep the right to change the instruction without prior notice.
Troubleshooting
Any troubleshooting work below done to the motor must be completed by a licensed
electrician and only whilst the power is off and the motor is unplugged!
Problem
Possible Reason
Solution
The gate cannot open
or close normally, and
LED does not light.
1. The power supply is
disconnected.
2. Fuse is blown.
3. Control board X1 terminal
wrongly wired.
1. Connect the power supply.
2. Check the fuse (FU) and replace if
blown.
3. Re-wiring according to user
manual.
The gate can only
open, but cannot
close.
1. Photocell wrongly wired.
2. Photocell wrongly
installed.
3. Photocell is blocked by
objects.
4. Sensitivity of obstacle is
too high (Intelligent type).
5. Hall sensor parts
damaged (Intelligent type).
1. If not connect photocell, please
ensure the infrared port and GND port
has a jumper wire; if connect photocell,
please ensure the wiring is correct and
the photocell status is N.C.
2. Ensure that the photocell mounting
position can be mutually aligned.
3. Remove the obstacle.
4. Reduce the sensitivity of obstacle.
5. Replace hall sensor parts.
Remote control
doesn’t work.
1. Battery level is too low.
2. Remote control not
paired.
1. Change the battery.
2. Pair the remote control to the gate
opener.
Press OPEN, CLOSE
button, the gate is not
moving, motor has
noise.
1. Capacitor damaged.
2. Capacitor is poor
connected.
3. Gate moving is not
smoothly
1. Change capacitor.
2. Check the capacitor wiring.
3. Adjust the motor or gate according to
the actual situation.
Not stop when
running to opening or
1. The opening or closing
limit switch is in opposite.
1. Check whether the limit switch wiring
is consistent with the motor running