Intermittent Problems
Intermittent system hang problems can be caused by a variety of reasons that
have nothing to do with a hardware defect, such as cosmic radiation,
electrostatic discharge, or software errors. FRU replacement should be
considered only when a recurring problem exists.
When analyzing an intermittent problem, do the following:
1
Run the advanced diagnostic test for the system board in loop mode at
least 10 times.
•
If any error is detected, replace the FRU.
•
If no error is detected, do not replace any FRU.
2
Rerun the test to verify that there are no more errors.
Undetermined Problems
The diagnostic problems does not identify which adapter or device failed,
which installed devices are incorrect, whether a short circuit is suspected, or
whether the system is inoperative.
Follow these procedures to isolate the failing FRU (do not isolate a
non-defective FRU).
To isolate a failing FRU:
1
Power-off the computer.
2
Visually check them for damage. If any problems are found, replace the
FRU.
3
Remove or disconnect all of the following devices:
•
Non-Gateway devices
•
Printer, mouse, and other external devices
•
Battery pack
•
Hard disk drive(s)
•
DIMM
•
CD-ROM/Diskette drive Module
•
PC Cards
4
Power-on the computer.
5
Determine if the problem has changed.
Important
Verify that all attached devices are supported by the computer.
Important
Verify that the power supply being used at the time of the failure is
operating correctly. (
See “Power System Check” on page 60.
)
Summary of Contents for EC38
Page 1: ... Gateway EC38 SERVICEGUIDE ...
Page 6: ...Contents iv ...
Page 14: ...CHAPTER 1 System Specifications 8 System Block Diagram ...
Page 30: ...CHAPTER 1 System Specifications 24 ...
Page 31: ...CHAPTER2 25 System Utilities BIOS Setup Utility BIOS Flash Utility ...
Page 41: ...www gateway com 35 ...
Page 51: ...www gateway com 45 10 Remove screws on the upper case 11 Remove the dummy card ...
Page 62: ...CHAPTER 3 Machine Disassembly and Replacement 56 ...
Page 83: ...CHAPTER5 77 Jumper and Connector Locations Top View Bottom View ...
Page 86: ...CHAPTER 5 Jumper and Connector Locations 80 ...
Page 89: ...www gateway com 83 Exploded Diagram ...
Page 90: ...CHAPTER 6 FRU Field Replaceable Unit List 84 ...
Page 91: ...www gateway com 85 ...
Page 92: ...CHAPTER 6 FRU Field Replaceable Unit List 86 ...
Page 93: ...www gateway com 87 ...
Page 113: ...APPENDIXC 107 Online support information ...
Page 116: ...Index 110 ...
Page 117: ......
Page 118: ...MAN GODZILLA SVC GDE R1 07 08 ...