Lift the processor air duct from the chassis.
Removing the processor air dam
If you are adding a second processor to a single processor system, you need to remove the
air dam located on the underside of the processor air duct.
To remove the processor air dam:
1
Follow the instructions in
“Preventing static electricity discharge” on page 41
. Make
sure that you turn off the server, then unplug the power cord(s) and all other cables
connected to the server.
2
Follow the instructions in
“Opening the server case” on page 42
.
3
Follow the instructions in
“Removing the processor air duct” on page 45
.
Caution
If you add a second processor to your server, you must remove the
processor air dam or the processor may overheat, causing possible
data loss and damage to the processor.