background image

7

Set up the microphone.

Choose an optimum microphone and fix in the main body with 
one-touch connector.

1 

Turn on power.

"POWER" button - PUSH

No.

□ 

No.

□ 

No.

0→

No.

No.

1→

No.

No.

0→

No.

2 

Choose an input number with the select 
button and numeric key.
Ex: Choose one from No. 0 to No. 2.

"SELECT" button - PUSH
[Number is forwarded sequentially every time "SELECT" button 
is pressed. 0 

 1 

 

・・

18 

 19 

 0 

 1 

 2. In addition, 

you can jump to any designated number by pressing a number 
with numeric key.]
1. Selecting procedure

"SELECT" button - PUSH (1st time)

"SELECT" button - PUSH (2nd time)

2. Selecting procedure

"2" button - PUSH

When "SELECT" button is pressed during the following 
procedure (during display of unit mass, belt width, span length 
input, and measured value), the number being chosen is 
displayed.

3 

When inputting a unit mass manually
Ex: Input 2.5g/mm wide x meter long
[See page 9 for input data.]

When inputting the unit mass from belt 
type.
Ex: Select 3GT.

 Input the belt width.
Ex: Input 25.4 mm.
[See page 8 for input data.]

 "MASS" button - PUSH
[ Input the unit mass (g/mm W x m L) in the order of blinking 
position on display screen by use of numeric key. If input is 
mistaken, press "MASS" button again to return the cursor to 
the first.]
"0" button - PUSH
"0" button - PUSH
"2" button - PUSH
"5" button - PUSH

 "MASS" button, PUSH (holding down for one second or more)
[Have belt types displayed on screen, and choose a belt type 
with "UP" button and "DOWN" button.]
"DOWN" button - PUSH
Place highlighted portion on 3GT.
Press "MEASURE" button for selecting.
3GT is displayed on screen.

M

=□□□

.

g/m

 "Allowable input capacity: 
0.1 - 999.9 g/mm x m]

M

=0□□

.

g/m

M

=00□

.

g/m

M

=002

.

g/m

M

00

.

g/m

4-1

4-2

 "WIDTH" button - PUSH
[Do the same as described above. When data above allowable 
capacity is input, the cursor returns to the first, and input of data 
is requested again.]
"0" button - PUSH
"2" button - PUSH
"5" button - PUSH
"4" button - PUSH

W

=□□□

.

mm/R

 "Allowable input capacity: 
000.1 - 999.9 mm"

W

=0□□

.

mm/R

W

=02□

.

mm/R

W

=025

.

mm/R

W

=025

.

mm/R

5 

 Input the span length.
[See page 8 for input data.]

 "SPAN" button - PUSH
[Do the same as described above.]

S

=□□□□

mm

 "Allowable input capacity: 
0001 - 9999 mm"

6 

Displays tension.

 Result is displayed as well as peep sound emitted and LED
 (green) turns on in 1.5 sec after reception of belt vibration sound.

 When LED (red) turns on, see "checking item" in measurement 

malfunction on page 3.

T = 122N
"Displays from 0.01 to 
99900N in three significant 
digits"

8-1 

Displays frequency.
Displays frequency after measurement 
of tension.

 "Hz" button - PUSH
[ Displays frequency corresponding to the measured tension.
When "Hz" button is pressed once again, the display returns to tension mode.]

f

=235

Hz

 "Displays from 10.0 to 5000 
Hz in three significant digits"

8-2 

 Start measurement.

1. Bring the measurement microphone closer in the vicinity of span 
center of measurement target as far as it is out of contact with the 
belt (measurement target).
2. "MEASURE" button - PUSH: LED (green) blinks and LCD 
displays 

    

.

3. Flip the belt span with a finger etc. to vibrate the wire: LCD 
displays 

    

.

The following measurement is performed by the microphone 
receiving sound without use of measure button for the 2nd time 
and on.
Since measurement is started by the microphone receiving sound, 
measurement is started as well even by a noise if it has a relatively 
stable sound pressure.
Result is displayed as well as peep sound emitted and LED (green) 
turns on in 1.5 sec after reception of belt vibration sound.

In measurement for the 2nd 
time and after, previous data 
is displayed first. Intorn the 
measurement data is 
renewed at the same time as 
peep sound.]

7 

Procedure

Description

Operation

Display screen

.Operation procedure of U-507

 

S No 02   2GT   

1.5GT  0.9  

3GT     2.5  

2GT     1.3  

Summary of Contents for U-507

Page 1: ...Input of span length Unit mass list of timing belt made by Gates Unitta Asia Unit mass list of V belt made by Gates List of standard installation tension of timing belt made by Gates Unitta Asia P P...

Page 2: ...a wrong manne Caution This marking shows that possibility of injury is present and only physical damage is likely when the unit is used in a wrong mann The classified pictorial marking below shows des...

Page 3: ...machine is stopped by turning off motor power supply or the lik The arm of flexible arm microphone is a universal pipe but must not be bent at an acute angle In addition do not bend the pipe within 20...

Page 4: ...rement standby is displayed after the 3rd time and on In case of frequency mode The value changes greatly in every measurement The value responds sensitively to the noise around background noise other...

Page 5: ...scillation of string set on the tension meter described on the right in calculating the belt tension Here the belt and the wire have a rigidity which is different from the string therefore U 507 measu...

Page 6: ...off function to turn off power in about five minutes from the last measurement so if power is off during use press POWER button again 2 Explanation of each part of U 507 Main part Measurement sensor m...

Page 7: ...es dual display with tension and frequency However CAT display is available only when inputting from preinstalled data Displays only for timing belt Displayed CAT value for tension and frequency are s...

Page 8: ...returns to the first and input of data is requested again 0 button PUSH 2 button PUSH 5 button PUSH 4 button PUSH W mm R Allowable input capacity 000 1 999 9 mm W mm R W mm R W mm R W mm R Input the s...

Page 9: ...corresponds to one piece for V belt and wire and one rib for V ribbed belt Note Unit mass of U 507 U 505 and U 305 is 10 times the input of conventional type U 303 since the input unit has been chang...

Page 10: ...scription of MASS button on page 5 and 6 for selecting Input a value manually by use of unit mass list on the next page as for special pitch and special belt which are not described below List of prei...

Page 11: ...27 0 0 95 25 7 11M 56 0 0 93 52 1 J section 9 0 0 95 8 6 L section 32 0 0 95 30 4 PK section 21 0 0 95 20 0 A 120 0 0 86 103 2 B 200 0 0 83 166 0 C 360 0 0 83 298 8 D 660 0 0 81 534 6 E 1020 0 0 72 7...

Page 12: ...T N N MIN MAX MIN MAX 210 155 125 260 310 410 520 625 730 830 440 325 260 545 650 860 1090 1310 1530 1740 530 795 1060 1325 1590 1855 2650 3050 2120 3445 1110 1670 2230 2780 3340 3895 5565 6405 4450 7...

Page 13: ...e and turn it several times to make the machine familiar and measure the tension of 2 spans on belt tension side and loosening side and take the average When tension of 2 spans is different more than...

Page 14: ...10 to 5000 Hz and measure in the same way as measurement of tension which enables certification easily Tension meter certifying device U 305 OS1 is also in market If you contact our sales department w...

Page 15: ......

Page 16: ...HEAD OFFICE 4 26 SAKURAGAWA 4 CHOME NANIWA KU OSAKA 556 0022 JAPAN TEL 06 6563 1284 FAX 06 6563 1285 July 15 2005 2 000 parts D...

Reviews: