7
Set up the microphone.
Choose an optimum microphone and fix in the main body with
one-touch connector.
1
Turn on power.
"POWER" button - PUSH
No.
□
No.
□
No.
0→
No.
1
No.
1→
No.
2
No.
0→
No.
2
2
Choose an input number with the select
button and numeric key.
Ex: Choose one from No. 0 to No. 2.
"SELECT" button - PUSH
[Number is forwarded sequentially every time "SELECT" button
is pressed. 0
→
1
→
・・
18
→
19
→
0
→
1
→
2. In addition,
you can jump to any designated number by pressing a number
with numeric key.]
1. Selecting procedure
"SELECT" button - PUSH (1st time)
"SELECT" button - PUSH (2nd time)
2. Selecting procedure
"2" button - PUSH
When "SELECT" button is pressed during the following
procedure (during display of unit mass, belt width, span length
input, and measured value), the number being chosen is
displayed.
3
When inputting a unit mass manually
Ex: Input 2.5g/mm wide x meter long
[See page 9 for input data.]
When inputting the unit mass from belt
type.
Ex: Select 3GT.
Input the belt width.
Ex: Input 25.4 mm.
[See page 8 for input data.]
"MASS" button - PUSH
[ Input the unit mass (g/mm W x m L) in the order of blinking
position on display screen by use of numeric key. If input is
mistaken, press "MASS" button again to return the cursor to
the first.]
"0" button - PUSH
"0" button - PUSH
"2" button - PUSH
"5" button - PUSH
"MASS" button, PUSH (holding down for one second or more)
[Have belt types displayed on screen, and choose a belt type
with "UP" button and "DOWN" button.]
"DOWN" button - PUSH
Place highlighted portion on 3GT.
Press "MEASURE" button for selecting.
3GT is displayed on screen.
M
=□□□
.
□
g/m
"Allowable input capacity:
0.1 - 999.9 g/mm x m]
M
=0□□
.
□
g/m
M
=00□
.
□
g/m
M
=002
.
□
g/m
M
=
00
2
.
5
g/m
4-1
4-2
"WIDTH" button - PUSH
[Do the same as described above. When data above allowable
capacity is input, the cursor returns to the first, and input of data
is requested again.]
"0" button - PUSH
"2" button - PUSH
"5" button - PUSH
"4" button - PUSH
W
=□□□
.
□
mm/R
"Allowable input capacity:
000.1 - 999.9 mm"
W
=0□□
.
□
mm/R
W
=02□
.
□
mm/R
W
=025
.
□
mm/R
W
=025
.
4
mm/R
5
Input the span length.
[See page 8 for input data.]
"SPAN" button - PUSH
[Do the same as described above.]
S
=□□□□
mm
"Allowable input capacity:
0001 - 9999 mm"
6
Displays tension.
Result is displayed as well as peep sound emitted and LED
(green) turns on in 1.5 sec after reception of belt vibration sound.
*
When LED (red) turns on, see "checking item" in measurement
malfunction on page 3.
T = 122N
"Displays from 0.01 to
99900N in three significant
digits"
8-1
Displays frequency.
Displays frequency after measurement
of tension.
"Hz" button - PUSH
[ Displays frequency corresponding to the measured tension.
When "Hz" button is pressed once again, the display returns to tension mode.]
f
=235
Hz
"Displays from 10.0 to 5000
Hz in three significant digits"
8-2
Start measurement.
1. Bring the measurement microphone closer in the vicinity of span
center of measurement target as far as it is out of contact with the
belt (measurement target).
2. "MEASURE" button - PUSH: LED (green) blinks and LCD
displays
.
3. Flip the belt span with a finger etc. to vibrate the wire: LCD
displays
.
The following measurement is performed by the microphone
receiving sound without use of measure button for the 2nd time
and on.
Since measurement is started by the microphone receiving sound,
measurement is started as well even by a noise if it has a relatively
stable sound pressure.
Result is displayed as well as peep sound emitted and LED (green)
turns on in 1.5 sec after reception of belt vibration sound.
In measurement for the 2nd
time and after, previous data
is displayed first. Intorn the
measurement data is
renewed at the same time as
peep sound.]
7
Procedure
Description
Operation
Display screen
5
.Operation procedure of U-507
S No 02 2GT
1.5GT 0.9
3GT 2.5
2GT 1.3
Summary of Contents for U-507
Page 15: ......