Body of tension meter

■ 

Accessory

 Power supply: (AAA type x 2 pieces) Alkaline dry cell is recommended.

 Outer dimension: 160 (H) x 59 (W) x 26 (D)

 Mass: 120 g

 Use and storage temperature range: -10

C to 50

C, below 80% (free from condensation)

11

.List of U-507 specification

1) Flexible arm type microphone

 ・

 Microphone outer diameter: 12.5 mm

 ・

 Total length: 170 mm

 ・

 Measurable frequency band: 10 Hz - 5000 Hz

 *

 Common to present U-303, 305, and 505

2) Carrying soft case

 ・

 Capable of containing the body of tension meter, flexible arm type microphone, etc.

3) Alkaline dry cell: AAA type x 2 pieces

4) U-507 operation manual

5) Inspection acceptance certificate

6) Certificate

[Option]
1) Cord type microphone

 ・

 Microphone diameter: 12.5 mm

 ・

 Total length: 1m

 ・

 Measurable frequency band: 10 Hz - 5000 Hz

As for installation tension of our toothed belt, no difference is generated between the measured value of U-507 and actual 
tension in the measurement range of note 1) - 3) below, and it is not necessary to set any tension correction factor.

Note 1) In measuring the installation tension, basically set the belt on the machine and turn it several times to make the machine 
familiar, and measure the tension of 2 spans on belt tension side and loosening side and take the average. When tension of 2 
spans is different more than 30% approx, adjust them almost equal and measure again.

Note 2) Measure with a span having the length more than 20 times the tooth pitch.
(Because a value higher than actual tension is displayed when the span is so short as to be affected by rigidity of belt itself.)

Note 3) Set the tension range more than 1/3 of standard installation tension.
(Because a value higher than actual tension is displayed when the tension is so low as to be affected by rigidity of belt itself.) 
Measurement in an extremely low tension range is sometimes impossible as is seen from the measurement principle of this 
tension meter.

Note 4) It is reasonably estimated that some difference from actual tension is generated as for special belt such as wide belt for 
transport and back-ribbed belt, so that simple calibration is required for checking tension which needs precision comparatively.

As for experienced machine, install the belt by a procedure provided for corresponding machine, certify the frequency with 
U-507 tension meter, and set the same frequency thereafter, thus controlling the tension.

Summary of Contents for U-507

Page 1: ...Input of span length Unit mass list of timing belt made by Gates Unitta Asia Unit mass list of V belt made by Gates List of standard installation tension of timing belt made by Gates Unitta Asia P P...

Page 2: ...a wrong manne Caution This marking shows that possibility of injury is present and only physical damage is likely when the unit is used in a wrong mann The classified pictorial marking below shows des...

Page 3: ...machine is stopped by turning off motor power supply or the lik The arm of flexible arm microphone is a universal pipe but must not be bent at an acute angle In addition do not bend the pipe within 20...

Page 4: ...rement standby is displayed after the 3rd time and on In case of frequency mode The value changes greatly in every measurement The value responds sensitively to the noise around background noise other...

Page 5: ...scillation of string set on the tension meter described on the right in calculating the belt tension Here the belt and the wire have a rigidity which is different from the string therefore U 507 measu...

Page 6: ...off function to turn off power in about five minutes from the last measurement so if power is off during use press POWER button again 2 Explanation of each part of U 507 Main part Measurement sensor m...

Page 7: ...es dual display with tension and frequency However CAT display is available only when inputting from preinstalled data Displays only for timing belt Displayed CAT value for tension and frequency are s...

Page 8: ...returns to the first and input of data is requested again 0 button PUSH 2 button PUSH 5 button PUSH 4 button PUSH W mm R Allowable input capacity 000 1 999 9 mm W mm R W mm R W mm R W mm R Input the s...

Page 9: ...corresponds to one piece for V belt and wire and one rib for V ribbed belt Note Unit mass of U 507 U 505 and U 305 is 10 times the input of conventional type U 303 since the input unit has been chang...

Page 10: ...scription of MASS button on page 5 and 6 for selecting Input a value manually by use of unit mass list on the next page as for special pitch and special belt which are not described below List of prei...

Page 11: ...27 0 0 95 25 7 11M 56 0 0 93 52 1 J section 9 0 0 95 8 6 L section 32 0 0 95 30 4 PK section 21 0 0 95 20 0 A 120 0 0 86 103 2 B 200 0 0 83 166 0 C 360 0 0 83 298 8 D 660 0 0 81 534 6 E 1020 0 0 72 7...

Page 12: ...T N N MIN MAX MIN MAX 210 155 125 260 310 410 520 625 730 830 440 325 260 545 650 860 1090 1310 1530 1740 530 795 1060 1325 1590 1855 2650 3050 2120 3445 1110 1670 2230 2780 3340 3895 5565 6405 4450 7...

Page 13: ...e and turn it several times to make the machine familiar and measure the tension of 2 spans on belt tension side and loosening side and take the average When tension of 2 spans is different more than...

Page 14: ...10 to 5000 Hz and measure in the same way as measurement of tension which enables certification easily Tension meter certifying device U 305 OS1 is also in market If you contact our sales department w...

Page 15: ......

Page 16: ...HEAD OFFICE 4 26 SAKURAGAWA 4 CHOME NANIWA KU OSAKA 556 0022 JAPAN TEL 06 6563 1284 FAX 06 6563 1285 July 15 2005 2 000 parts D...

Reviews: