Optional Water Alarm
If your Gates housing includes the optional water alarm, there are three alarm conditions
to watch for:
You can test the alarm anytime by shorting the flood contacts that lead to the water
alarm transducer. The flood condition will activate for 6 seconds. If the battery is low,
the low battery condition will sound.
The battery for the water alarm is a single 9V type. Gates recommends the battery be
changed once a year.
O-ring Care and Maintenance
Your Gates housing for Panasonic
HVX200
has 3 serviceable o-rings. One is located
between the mating halves of the housing (the large orange one), and the other two are
located on the rear of each Port.
Servicing the o-rings is easy, and is covered in the “O-Ring Care and Maintenance”
document in this package.
a
Caution:
Do not lubricate the large orange o-ring! It is a special silicone o-
ring and can be damaged by petroleum-based lubricants.
a
Caution:
Never
use metal tools or objects for removing o-rings!
Customer Support
If you have any questions or require further assistance with your
HVX200
housing,
contact your dealer or Gates directly and we’ll be happy to assist.
Email:
Phone: 858-272-2501
Fax:
858-272-1208
Condition
LED
(if installed)
Siren
(always installed)
New Battery (when
inserted)
Bright intense blink for 6
seconds
Screaming sound for 6
seconds
Flood
Bright intense blink
Screaming sound. Alarm
will sound for duration of
flood + 6 seconds.
Low Battery
Low intensity fast blink
Intermittent chirp for 40
seconds after flood con-
dition.