comply with the following Essential Requirements of Directive 2006/42/CE Annex I (Machinery directive):

1.1.2 1.1.3 1.1.S 1.2.1 1.2.2 1 .2.3 1.2.6 1.3.2 1.3.4 1.3.9 1.4.1 1.4.2.1 1.5.1 1.5.4 1.5.6 1.5.8 1.5.13 1.6.1 1.6.4 1.7.1 1.7.3 1.7.4 

are in conformity with the following directives: 

2004/108/CE (electromagnetic compatibility) 

1999/5/CE (R&TTE) 

2011 /65/CE (directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment) 

The above listed products are delivered, limitedly to the applicable parts, according to the following standards:

- EN 12453 

 Industrial, commercial and garage doors and gates. 
Safety in use of power operated doors. Requirements

- EN 12445 

 Industrial, commercial and garage doors and gates. 
Safety in use of power operated doors. Test methods 

- EN60335-1 

 Safety of household and similar electrical appliances - 
Part I: General requirements

- EN60335-2-103 

 Household and similar electrical appliances - 
Part 2-103: Particular requirements for drives for gates, doors and windows

They also state that:

 the relevant technical documentation is compiled in accordance with part B of Annex VII of directive 2006/42/CE 

 the relevant technical documentation is compiled and preserved by PROTECO SRL which undertakes to transmit it by mail in 
response to a reasoned request by the national authorities.

 the partly completed machinery must not be put into service until th final machinery into which it is to be incorporated has 
been declared in conformity with the provisions of the directive 2006/42/CE

EU DECLARATION OF CONFORMITY 

This compliance declaration combines the content of separate compliance declarations for any product 

mentioned; a copy of the original compliance declaration of each product can be obtained from PROTECO Sri.

Marco Gallo

Managing Director

January 19th 2016

Summary of Contents for MyGate myAster Series

Page 1: ...VISION 2019 2 automationKitforswinggates myAster GateMotors 44 0 1202 744958 Technical support 44 0 1202 725489 www gatemotors co uk Sales and Accessories 44 0 1202 717191 ENGLISH Installation Manual...

Page 2: ...move all manual locks and bolts In the event of a power cut the gate motor can be released by manual operation Use of the product must be restricted to its intended use Any other use is to be consider...

Page 3: ...screw RECOMMENDED GATE LEAF FIXINGS not included GateMotors 44 0 1202 744958 Technical support 44 0 1202 725489 www gatemotors co uk Sales and Accessories 44 0 1202 717191 myAster dimensions 50 mm 11...

Page 4: ...00 rpm 1400 rpm Leaf s maximum length 2000 mm 2000 mm 2500 mm 2750 mm 3000 mm 3500 mm 4000 mm Leaf s maximum weight 275 Kg 350 Kg 250 Kg 350 Kg 150 Kg 250 Kg 250 Kg Maximum opening 110 110 110 110 110...

Page 5: ...mm Left motor Right motor INWARD FACING Check that the open position of the automated gate is not an entrapment hazard with regards to any surrounding buildings or fixed objects and there is sufficie...

Page 6: ...m 140 mm 140 mm Minimum leaf length 1150 mm 1130 mm 1130 mm 1130 mm 1140 mm 1120 mm 1100 mm 1070 mm 1050 mm myAster 5 D 275 mm 250 mm 225 mm 200 mm 175 mm 150 mm 125 mm 100 mm 75 mm A 275 mm 300 mm 29...

Page 7: ...ecreased by the same amount as the A measurement is increased For example If installing the myAster 3Ti measurement A increasing 20 mm now 170 mm means measurement B ideally decreases 20 mm now 130 mm...

Page 8: ...ill return to its default settings Manual release NB Check the manual opening of the gate leaf before definitively fixing the bracket S3 to make sure the gate can open fully to your required angle To...

Page 9: ...conduits for the electrical cables feed the motors control panel and accessories separately in order to prevent interferences that may result in bad operation Fit the power cable keeping a curve as s...

Page 10: ...ent removal tampering of any labels attached to the product will invalidate the warranty Transferring the warranty to any other person The warranty is only applicable to the original purchaser Under n...

Page 11: ...er operated doors Requirements EN 12445 Industrial commercial and garage doors and gates Safety in use of power operated doors Test methods EN60335 1 Safety of household and similar electrical applian...