3. Specification
3.1. Basic Specifications
3.2. Mechanical Specifications
ITEMS
SPECIFICATION
Measuring Type
Diffusion
Measuring Value Display
Local Digital LCD or OLED Display
Measuring Method
- Catalytic Cell)
- Thermal Conductivity Cell
- Heated-semiconductor Cell
Detectible Gas
Flammable gas
Measuring Range
0~100% LEL
Accuracy
≤ ±3% / Full Range
Zero Drift
≤ 2% / Full Range
Response Time
90% of full Scale in less than 15 sec
Approvals Classification
KCs: Ex d llC T6, T5, T4, IP65
Basic Interface
Analog 4-20mA current interface
HART Interface
HART REV7(Option)
Option
HART Board
MODBUS RS485 Board
GTL-100 Warning Light
Rain Cover
Warranty
Transmitter
2Year
Sensor
1Year
ITEMS
SPECIFICATION
Explosion Proof type
Explosion-Proof Enclosure
Dimension
156(W) × 322(H) × 110(D) mm
Weight including Sensor
App. 1.8kg
Mounting type
Wall mount
Mounting Holes
Ø 7 ±0.1
Cable inlet
3/4" PF (1/2" or 3/4" NPT)
Body material
Transmitter)
aluminum alloy
Sensor
Stainless Steel (STS316)