Instruction Manual
- By pressing "UP" S/W or "DOWN" S/W, ON/OFF status can be set and when it is ON, UNDER
-
function is available for use. (Default OFF)
- When a desired item is displayed, press "FUNC" S/W to set it and enter the next item.
- When "RESET" S/W is pressed, it enters Option Setting Mode.
- For measurement display, it displays raw data from -XXXX ~ +YYYY.
- When "FUNC" S/W is pressed, it enters "Engineer" setting mode.
- When "RESET" S/W is pressed, it enters Option Setting Mode.
- (This mode is only used as test mode and is not used in the actual field.)
- By pressing "UP" S/W or "DOWN" S/W, ON/OFF status can be set and when it is ON,
-
the function is available for use. (Default OFF)
- When a desired item is displayed, press "FUNC" S/W to set it and enter the next item.
- When "RESET" S/W is pressed, it enters Option Setting Mode.
- Item for zero skip setting.
- It zero skips the value designated for high scale setting range.
- When "FUNC" KEY is pressed, it enters Z-S setting mode.
- When "RESET" KEY is pressed, it returns to Option Setting Mode.
- It can set in 0~20 (%) range using "▲" KEY or"▼(Test)" KEY.
- When a desired value is displayed, press "FUNC" KEY to set and enter the next item.
- When "FUNC" KEY is pressed, it enters Option Setting Mode.
- Item for span skip setting.
- It span skips the value designated for high scale setting range.
- When "FUNC" KEY is pressed, it enters S-S setting mode.
- When "FUNC" KEY is pressed, it enters Option Setting Mode.
- It can set in 0~20 (%) range using "▲" KEY or"▼(Test)" KEY.
- When a desired value is displayed, press "FUNC" KEY to set and enter the next item.
- When "FUNC" KEY is pressed, it enters Option Setting Mode.
- It sets Emergency Time Out. In stand-by mode, the user can decide whether to set the time.
- When "FUNC" KEY is pressed, it enters Emergency Time Out setting mode.
- When "RESET" KEY is pressed, it returns to Option Setting Mode.
- By pressing ""▲" KEY or"▼(Test)" KEY, ON/OFF status can be set. When it is ON, mode time
-
runs for 30 min and when it is OFF, stand-by mode time continuously runs without limit.
-
(Default OFF)
- When a desired item is displayed, press "FUNC" KEY to set and enter the next item.
- When "RESET" KEY is pressed, it returns to Option Setting Mode.
- It sets output delay time
- Gas value within time and value applied by operating with output delay value is not displayed.
- When the value exceeds, the measurement is displayed.
- When "FUNC" KEY is pressed, it enters Output Delay Time setting mode.
- When "FUNC" KEY is pressed, it enters Option Setting Mode.
- It can set in 0~60 (sec) range using "▲" KEY or"▼(Test)" KEY.
- When a desired value is displayed, press "FUNC" KEY to set and enter the next item.
- When "FUNC" KEY is pressed, it enters Option Setting Mode.
-
※ odt and odv settings operate by referencing each other.
▼ ▲
▼ ▲
▼ ▲
6. Operation Method