It is the function using "FUNC" S/W, the cases for consecutive pushing of S/W occur.
-
When "FUNC" S/W is operated upon Yes/no to prevent this, "1" -> "11" -> "111" -> "1111" is
-
outputted in FND from the left side by the unit of 0.5s .
-
Upon selection of "YES" , initialization is completed, and the display state of gas concentration is
-
returned to.
-
Upon selection of "no" , the display state of gas concentration is returned to without initialization.
-
Upon selection of "RESET" S/W, the display state of gas concentration is returned to without
-
outputting in FND.
www.gastron.com
36
_
37
GTC-520A
Instruction Manual
▼
6.5.9. Initialization function for calibration data(Calibration Initial)
■ When the power supply is turned ON with "FUNC" S/W + "DOWN" S/W pushed, it can be entered into.
■ Calibration Initial is the function for initialization only of calibration value among product's setting values to the
basic setting value upon factory shipment.
-
Mode where only calibration data among the currently saved data to the existing data upon
-
factory shipment.
-
When "RESET" S/W is pushed, the display state of gas concentration is returned to.
- Enter by pushing "FUNC" S/W.
- Yes/no states can be set by using "UP" S/W or "DOWN" S/W. In the case of Yes, Calibration
-
Initial function can be used. (Initial value no)
- When "RESET" S/W is pushed, the display state of gas concentration is returned to.
- It is the function using "FUNC" S/W, the cases for consecutive pushing of S/W occur.
- Enter by pushing "FUNC" S/W.
- Yes/no states can be set by using "UP" S/W or "DOWN" S/W. In the case of Yes, Calibration
-
Initial function can be used. (Initial value no)
- When "RESET" S/W is pushed, the display state of gas concentration is returned to.
▼ ▲
7.1. MODBUS RS485
7.1.1. Interface setting
7.1.2. MODBUS RS485 Register map
■ Data Format: RTU
■ Baud rate: 9600 bps
■ Data bits: 8bits
■ Stop bit: 1bits
■ Parity: Even
■ Please see www.modbus.org for other details
CLASSIFICATION
ADDRESS
BITS
DESCRIPTION
Concentration of
measured gas
30001
BIT15~0
Gas measured value(Integer type / Decimal Point not
considered)
Setting value for
High Scale
30002
BIT15~0
Setting value for High Scale (Integer type / Decimal Point
not considered)
Setting value for
1st Alarm
30003
BIT15~0
Setting value for 1st Alarm (Integer type / Decimal Point not
considered)
Setting value for
2nd Alarm
30004
BIT15~0
Setting value for 2nd Alarm (Integer type / Decimal Point
not considered)
State value for
Gas detector
10000
BIT0
Alarm 1 Active state
BIT1
Alarm 2 Active state
BIT2
Fault Active state
BIT3
Maintenance Mode state
BIT4
Test Mode state
BIT5
Calibration Mode state
BIT6
Reserved
BIT7
Toggle Bit(Bit inversion at an interval of 2 Sec)
Outside Test
3
BIT0~7
Set for Gas detector Test Mode
Outside Reset
2
BIT0~7
Gas detector Test Mode
7. Interface configuration
6. How to operate
[Table 5.Configuration of RS485 MODBUS Address]