Gast 6066 SERIES Operation & Maintenance Manual Download Page 8

TROUBLESHOOTING CHART

Low

High

Pump

Motor

Reason and remedy

Vacuum Pressure

Vacuum

Pressure

Overheat Overload for problem.

At pump

Filter dirty.

Clean or replace.

At pump

Muffler dirty.

Clean or replace.

At pump

Vacuum line collapsed.

Repair or replace.

Relief valve set too high.

Inspect and adjust.

Relief valve set too low.

Inspect and adjust.

At pump

At pump

Plugged vacuum/pressure line.

Inspect and repair.

Vanes sticking.

Clean or replace.

Vanes worn.

Replace.

Shaft seal worn.

Replace.

Dust or offset powder in pump.

Inspect and clean.

Motor not wired correctly.

Check wiring diagram and line voltage.

Running at too high an RPM.

Check wiring diagram and line voltage.

www.gastmfg.com

ISO 9001 & 14001 CERTIFIED

We have Gast Certified Service Centers throughout the world.

For the most up-to-date

listing, contact one of our sales offices below:

Gast Hong Kong

Room 6,9/F

New Commerce Centre

19 on Sum Street, Shatin

N. T. Hong Kong

Ph: (852) 2690 1066

Fax: (852) 2690 1012

www.gasthk.com

European Sales & Service Headquarters

Gast Group Limited

A Unit of IDEX Corporation

Unit 11, The I O Centre

Nash Road

Redditch B98 7AS

United Kingdom

Tel: +44 (0) 1527 504040

Fax: +44 (0) 1527 525262

www.gastmfg.com

www.jun-air.com

Gast Manufacturing, Inc.

P.O. Box 97

2300 S. Highway M139

Benton Harbor, MI 49022

Ph: 269/926-6171

FAX: 269/925-8288

www.gastmfg.com

Summary of Contents for 6066 SERIES

Page 1: ...rotect all surrounding items from exhaust air This exhaust air can become very hot Corrosive gases and particulate material will damage unit Water vapor oil based contaminants or other liquids must be filtered out Consult your Gast Distributor before using at high altitudes Oil Less rotary vanes require NO lubrication Sealed bearings are grease packed Use of petroleum or hydrocarbon products will ...

Page 2: ...filter to prevent contaminants from entering the pump or the pneumatic system Please consult your Gast Distributor Representative for additional filter recommendations c Disconnect electrical power at the circuit breaker or fuse box before installing this product Install this product where it will not come into contact with water or other liquids Install this product where it will be weather prote...

Page 3: ... Power supply wiring must conform to all required safety codes and be installed by a qualified person Check that supply voltage agrees with that listed on product nameplate Be sure the 3 phase motor turns in the proper direction of rotation after installation Turning in the wrong direc tion will drastically reduce vane life Extension cords Use only a 3 wire extension cord that has a 3 blade ground...

Page 4: ... and exhaust ports 10 Replace filter before resuming operation Check intake and exhaust filters after first 500 hours of operation Clean filters and determine how frequently filters should be checked during future operation This one procedure will help to assure the productʼs perform ance and service life Clean filters when necessary by removing and washing in a solvent or soap and water After cle...

Page 5: ...en place one of the new bearings in the seat Using an arbor press press the bearing onto the shaft Be careful to press only on the inner bearing race Tighten the pump body bolts 7 Install the new vanes supplied with the kit Be careful to face the vane bevels in the proper direction as noted in step 2 8 Perform step 6 from Minor Rebuild 9 Install the belleville springs with the washer between them ...

Page 6: ...VE 1 AK736 AK736 17 IFAN GUARD ASSM DEAD 1 AK737 AK737 18 INTAKE FILTER ASSEMBLY 1 AD560 AD560 19 MUFFLER ASSEMBLY 1 AD560C 20 COVER GASKET 1 AD562 2 AD562 21 JAR 1 AD563A 2 AD563A 22 FILTER ELEMENT ASSEMBLY 1 AD750 2 AD750 23 FILTER FELT 1 AD752 2 AD752 24 BODY SPACER 1 AE315B 2 AE315B 25 KEY COUPLING 1 AE136D AE136D 26 COUPLING ASSEMBLY 1 AE765 AE765 27 CHECK VALVE NOT SHOWN 1 AH326B AH326B SERV...

Page 7: ...UENTIAL DAMAGES OF ANY KIND however arising including but not limited to those for use of any products loss of time inconvenience lost profit labor charges or other incidental or consequential damages with respect to persons business or property whether as a result of breach of warranty negligence or otherwise Notwithstanding any other provision of this warranty BUYER S REMEDY AGAINST GAST FOR GOO...

Page 8: ...eck wiring diagram and line voltage Running at too high an RPM Check wiring diagram and line voltage www gastmfg com ISO 9001 14001 CERTIFIED We have Gast Certified Service Centers throughout the world For the most up to date listing contact one of our sales offices below Gast Hong Kong Room 6 9 F New Commerce Centre 19 on Sum Street Shatin N T Hong Kong Ph 852 2690 1066 Fax 852 2690 1012 www gast...

Reviews: