5.0  Periodical Maintenance 

Attention: do not use water to clean the heater!! 

Arrange for an annual inspection by a qualified technician. Clean the heater with compressed air after each round and 
clean the filter, in necessary with water & soap, when needed.  
 

6.0  Problem shooting 

Problems can occur in the following areas: 

A: 

Gas supply 

 

B

= Electricity supply 

 

C

= Control and/or Safety units 

Please contact your gas technician in case there are problems. 
 

6.1 Problem solving. 

The most common problem causes are:  

a) Dirty air filter / dirty venturi 

 

d) Pilot flame guard damaged  

b) Dirty main jet / pilot jet  

 

e) No electricity supplied to the heater for the G12 Asco 

c) Thermo couple damaged 

 

f) Incorrect gas pressure to the heaters, either too high or too low 

 

7.0  Spare parts:

 : When ordering spare parts please give details of the heater for which the parts are to be used, like:    

 Heater type, gas type, pressure range, connection voltage, year of constructions, type of controller, etc. 

 

G12-ASCO 

G12-MAXI 

51  Connection Eye rod 

PG010 

51 

Connection Eye rod 

PG010 

52  Connection Rod 

PG011 

52 

Connection Rod 

PG011 

53  Reflector G12 

PG012 

53 

Reflector G12 

PG012 

54  Short spacer, 10*12mm 

PG013 

54 

Short spacer, 10*12mm 

PG013 

55  Emitter G12 top plate 

PG014 

55 

Emitter G12 top plate 

PG014 

56  Emitter G12 

PG015 

56 

Emitter G12 

PG015 

57  Emitter G12 Bottom Plate  

PG016 

57 

Emitter G12 Bottom Plate  

PG016 

58  Long spacer, 10*100mm 

PG021 

58 

Long spacer, 10*100mm 

PG021 

59  Burner G12 complete 

PG022 

59 

Burner G12 complete 

PG022 

60  Venturi G12 

PG029 

60 

Venturi G12 

PG029 

61  Adapter 

PG030 

61 

Adapter 

PG030 

62  HD Dust Filter 

PG032 

62 

HD Dust Filter 

PG032 

63  Jet G12 

PG *) 

63 

Jet G12 

PG *) 

64  Jet holder G12 

PG035 

64 

Jet holder G12 

PG035 

65  Jet Retainer G12 

PG036 

65 

Jet Retainer G12 

PG036 

66  Solenoid Asco  

PG040 

71 

Pilot flame cover G12 

PG120 

67  Bushing 1/4*1/8 

PG075 

72 

Thermocouple holder G12 

PG121 

68  Safety device G12 

PG048 

73 

Pilot Jet G12 

PG *) 

69  Thermocouple 600mm 

PG070 

74 

Washer M6 

PG080 

70  Pilot gas pipe incl. Nuts and 

compression fittings for G12-Asco  

PG100 

75 

Chain G12 

PG085 

71  Pilot flame cover G12 

PG120 

76 

M6 Nylock Nut 

PU041 

72  Thermocouple holder G12 

PG121 

77 

Lock Ring M8 

PG081 

73  Pilot Jet G12 

PG *) 

79 

Screw M6*16 

PU042 

74  Washer M6 

PG080 

81 

Nut M6 

PU044 

75  Chain G12 

PG085 

82 

Lock Ring M6 

PU045 

76  M6 Nylock Nut 

PU041 

84 

Screw M5*10 

PU036 

77  Lock Ring M8 

PG081 

91 

Maxitrol Thermostat Unit 

PG050 

79  Screw M6*16 

PU042 

92 

Elbow  3/8M*3/8F  

PG130 

80  Burner Pipe Support G12 Asco 

PG038 

93 

Bushing 3/8*1/4  

PG131 

81  Nut M6 

PU044 

94 

Hose socket*3/8M 90grad brass 

PG132 

82  Lock Ring M6 

PU045 

95 

Sensor bracket, incl. 2 x (rivet + 
spring ring + bracket) 

PG055 

83  Hose socket G12 

PU130 

96 

Sensor bracket 

PG053 

84  Screw M5*10 

PU036 

97 

Burner pipe support G12 Maxi  

PG039 

 

*) = size jet depending on gas type & 
gas pressure 

 

98 

Pilot gas pipe incl. nuts and 
compression fittings for G12-Maxi 

PG101 

 

 

 

99 

Thermocouple 600mm G12-Maxi 

PG070 

 
 

Summary of Contents for G12-Asco

Page 1: ...lec G12 Asco G12 Maxi UK Manual 2 4 11 12 DE Installations und Bedienungsanleitung 5 7 11 12 ES Manual 8 12 Gasolec B V P O Box 183 2410 AD Bodegraven The Netherlands Tel 31 0 172 636 636 Fax 31 0 172 636 630 E mail info gasolec com CE 0085BL0022 ...

Page 2: ... at all times when working on the heater Check the electric wiring before using the heater for the first time on damage Damaged lines should be replaced before using the equipment Only a qualified electrician should do repairs on cable connectors Never unplug a cable from a socket by pulling on the wire 1 1 Maintenance Disconnect the power and gas supply before working on a heater Qualified techni...

Page 3: ... materials See also 2 Technical data Verify the gas pressure in the gas line to the heater To calibrate the gas pressure to the heater one should use a manometer for 0 60mBar It is essential at all time to adhere to the national rules as well as the guidelines of the energy supplier s 3 4 Conversion Your local gas technician should do a conversion of a heater to an other gas type and or gas pressu...

Page 4: ...om Plate PG016 57 Emitter G12 Bottom Plate PG016 58 Long spacer 10 100mm PG021 58 Long spacer 10 100mm PG021 59 Burner G12 complete PG022 59 Burner G12 complete PG022 60 Venturi G12 PG029 60 Venturi G12 PG029 61 Adapter PG030 61 Adapter PG030 62 HD Dust Filter PG032 62 HD Dust Filter PG032 63 Jet G12 PG 63 Jet G12 PG 64 Jet holder G12 PG035 64 Jet holder G12 PG035 65 Jet Retainer G12 PG036 65 Jet ...

Page 5: ...rchgeführt werden Bei allen Arbeiten am Gerät dieses unbedingt von der Stromversorgung trennen Elektrische Leitungen vor Inbetriebnahme auf Schäden untersuchen Schadhafte Leitungen gegebenenfalls auswechseln Gerät darf vorher nicht in Betrieb genommen werden Beschädigte oder zerstörte Steckverbindungen nur durch einen Elektrofachmann ersetzen lassen Den Stecker niemals an der Leitung aus der Steck...

Page 6: ...mBar Andere Drucke auf nachfrage Nach der Installation ist der Druck in der Leitung beim Strahler zu überprüfen mittels ein Druckmanometer 0 60mBar Die Vorschriften der örtlichen Behörden und Energieversorgungsunternehmen sind einzuhalten 3 4 Umbau Den Umbau auf eine andere Gasart muss ihr Installateur vornehmen Für den Umbau von Erdgas nach Propan oder umgekehrt soll ein Umbausatz verwendet werde...

Page 7: ...kel PG016 57 Glühkörper G12 Unterdeckel PG016 58 Rohr lang Nirosta 10 100mm PG021 58 Rohr lang Nirosta 10 100mm PG021 59 Brenner G12 komplett PG022 59 Brenner G12 komplett PG022 60 Venturi G12 PG029 60 Venturi G12 PG029 61 Adapter PG030 61 Adapter PG030 62 HD Staub Filter PG032 62 HD Staub Filter PG032 63 Düse G12 PG 63 Düse G12 PG 64 Düsenhalter G12 PG035 64 Düsenhalter G12 PG035 65 Düsenhalter K...

Page 8: ...imiento normal del aparato deben ser realizadas únicamente por un técnico calificado Siempre desconecte la alimentación eléctrica cuando vaya a realizar trabajos en el calefactor Antes de utilizar el calefactor por primera vez compruebe si el cableado eléctrico presente daños Los cables dañados deben ser reemplazados antes de utilizar el aparato Las reparaciones en conectores de cable deben ser re...

Page 9: ...una sala con calefactores Es posible lograr un régimen de refrigeración de 1 00 en una sala con ventilación natural si se realizan 2 aberturas Cada abertura debería ser por lo menos 60 x B cm2 si B es la capacidad instalada de calefacción en kW h En caso de utilizar ventilación mecánica y suponiendo una distribución uniforme de aire fresco se requiere una capacidad de ventilación de 1 5m3 kW h cua...

Page 10: ...re sucio Venturi sucio b surtidor principal sucio surtidor piloto sucio c termopar dañado d dispositivo de seguridad de llama pilot dañado e no se suministra electricidad al calefactor para el G12 Asco f presión de gas incorrecta para los calefactores o bien demasiado alta o bien demasiado baja 7 0 Piezas de recambio Cuando pide piezas de recambio le rogamos nos facilite los datos técnicos del cal...

Page 11: ...rnillo M6 16 PU042 92 Codo 3 8M 3 8F PG130 80 Soporte tubo quemador G12 Asco PG038 93 Machón reducción 3 8 1 4 PG131 81 Tuerca M6 PU044 94 Empalme manguera 3 8M 90 grados latón PG132 82 Anillo de seguridad M6 PU045 95 Soporte sensor incl 2 x remache arandela elástica soporte PG055 83 Empalme manguera G12 PU130 96 Soporte sensor PG053 84 Tornillo M5 10 PU036 97 Soporte tubo quemador G12 Maxi PG039 ...

Page 12: ...G12As Max Manual De Eng ES 2013 doc 12 12 Gasolec G12 Maxi A 130 150cm B 120cm C 40cm o k ...

Reviews: