9
8
8
TEST FIRING APPLIANCE
Test fire appliance, following the lighting instructions
found on the appliance. Leak test all gas connections
with soapy water. Soap bubbles indicate gas leakage.
DO NOT use a flame to test for gas leaks.
WARNING: White smoke may appear
around the burner during the first minute of
the initial firing.
9. In the event that the flame goes out (due to wind
or other reasons) the flame failure device will
automatically shut off the gas supply after 60
seconds. To re-light start lighting process from Step 1.
10. To turn ‘OFF’ the appliance turn control knob to the
‘OFF’ position.
11. Open LPG compartment panel and turn the LPG
cylinder valve to ‘OFF’ position.
12. Allow the appliance to cool before moving and
covering for storage (at least 30 minutes).
Note: If for some reason, igniter fails to produce a spark
at the electrode, fire bowl can be lit by a long match.
Move glass beads to gain access to the burner (DO NOT
touch unless completely cool). Wearing heat resistant
gloves, position long lit match close to burner port. DO
NOT lean over burner while lighting.
Push and turn burner control knob to “LOW” position.
The burner should light within 5 seconds.
STORAGE & MAINTENANCE
To obtain the best performance from your fire table, you
must perform the following storage and maintenance
activities on a regular basis:
• Allow at least 30 minutes for the fire table to cool
down after use, then disconnect and remove the
cylinder.
• Store the gas cylinder in a dry, well ventilated and
sheltered area away from weather and dust, out of the
reach of children, and not in a building, garage or any
other enclosed area.
• Storage indoors is permissible only if the cylinder is
disconnected and removed. It is recommended that
the fire table be stored indoors during the winter if it
will be subjected to freezing temperatures.
• Keep the fire table area clear and free from
combustible materials, gasoline and other flammable
vapors and liquids.
• If the fire table is not in use, it must be covered to
protect from weather or other adverse elements.
• Never use a vacuum cleaner on the glass beads.
• Installation and repair should be done by a qualified
service person.
• The fire table should be inspected at least annually
by a qualified service person. It is imperative that
control compartment, burners and circulating air
passageways of the fire table be kept clean.
TEST FIRING APPLIANCE
For first time use and after every change of LPG cylinder
the gas system must be purged of air before lighting. To
do this, turn your LPG cylinder valve on and push in and
turn the control knob to ‘HIGH’ position. Hold in control
knob for 1 minute before attempting to light appliance.
1. Make sure that the control knob is in the ‘OFF’ position.
2. Remove LPG compartment panel to gain access to
LPG cylinder. Turn cylinder valve to ‘ON’ position and
replace panel.
3. Push in the control knob and keep depressed while
turning to the ignition point marked with a ‘ ’ or
‘LOW’. Once the control knob is at this point push the
ignition button. The Igniter will spark automatically, if
it does not spark, release control knob and return to
the ‘OFF’ position. Then check if battery is inserted
correctly or if the ignition wire has come loose under
the burner.
4. When the burner is lit and flames are visible in the
‘LOW’ position release ignition button but keep the
control knob depressed for a further 20 seconds and
then release it.
5. If the burner does not stay
lit, turn off control knob and
the cylinder valve and wait
5 minutes and repeat from
Step 1.
6. Burner is now lit in the
‘LOW’ position.
7. Adjust the flame and heat
output by turning the control
knob from ‘LOW’ to ‘HIGH’
a few times to check the
flame stability.
8. Adjust control knob to desired output between ‘LOW’
and ‘HIGH’.
IMPORTANT: Cover must be removed
when burner is in operation.
Summary of Contents for URBO GM142-163
Page 10: ...10 This page has been intentionally left blank ...
Page 11: ...11 This page has been intentionally left blank ...
Page 12: ...12 ...