WARNINGS
• Improper installation, adjustment, alteration, service
or maintenance can cause injury or property
damage.
• Read the instructions thoroughly before installing or
servicing this equipment.
• THIS APPLIANCE MUST NOT BE INSTALLED OR
USED INDOORS.
• NATURAL GAS APPLIANCE. TO BE INSTALLED
ONLY BY AN AUTHORISED PERSON.
• THE AUTHORISED PERSON WILL PROVIDE A
CERTIFICATE OF COMPLIANCE.
• A suitable AGA approved natural gas pressure
regulator must be installed in the pipeline and be set
at 1 kPa.
NATURAL GAS CONVERSION
TO BE INSTALLED ONLY ON OR IN A NON-
COMBUSTIBLE ENCLOSURE
Note: Recommended clearances must be maintained.
Tools Required:
• Adjustable spanner
• Phillips head screwdriver
GAS PIPING
1. (a) A minimum pipe diameter of 15mm is required for inlet
piping. A lever operated shut-off valve should be
installed within 1 metre of the appliance for servicing
the unit.
(b) Where it is not practical to install solid tube AGA
certified to AS/NZS 1869 class A stainless steel
braided hose can be installed. This hose assembly
must comply with AS5601 Gas Installations, pipe
sizing tables and shall not exceed 3 metres in
length. The internal diameter of the hose must not
be less than 10mm.
2. Check with local and state plumbing and heating
codes regarding sizing of the gas lines.
3. All gas pipe connections must be sealed with a gas
pipe compound resistant to Natural Gas.
4. Installation of a drip leg if required in the gas supply
line must conform to AS5601.
5. When checking for gas leaks, do not use an open
flame. Use a soap and water solution and check for
bubbles indicating gas leakage.
6. Installation of 1/8” NPT plugged tapping, accessible
for test gauge connections, is required upstream of
the gas supply connection.
Warning
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Read
the instructions thoroughly before installing or servicing
this equipment.
SERVICING INSTRUCTIONS
Appliances should be serviced at least annually and
servicing must only be carried out by a Licensed Plumber
or Authorised Person.
Clean the Burner Ports and top with a Soft Brush.
Inspect and clean all combustion air inlets, then replace
the Burner ensuring it is firmly secured.
Minimum Clearance for Ventilation:
Rear
600 mm
Side
600 mm
NOTE TO INSTALLER:
1. The gas valve plug by-pass orifices must be increased
to:
BBQ Burner
- 1.15mm
Side Burner
- 1.00mm
2. Drill the injector as per the data label specifications or
contact customer service on 1300 174 876 to order
an injector kit.
3. The gas hose connection point orifice must be
increased to O 7.0mm.
4. The gas hose connection point is inside the right
hand cabinet at the rear, 50cm up from the base
panel.
Air for combustion is provided by openings in the
side and bottom of the combustion chamber.
TEST OPERATION OF APPLIANCE
BEFORE LEAVING.
Conversion ONLY to be done by an authorised person.
Overall Dimensions
Length
Width
Height
BQ1010P
117cm
60cm
116cm
BQ1011P
146cm
60cm
116cm