The following figures are diagrammatical representations of outdoor areas.  Rectangular areas have been 
used in these figures - the same principles apply to any other shaped area.

SAFE APPLIANcE LOcATIONS

This appliance shall only be used in an above ground open-air situation with natural ventilation, without 
stagnant areas, where gas leakage and products of combustion are rapidly dispersed by wind and 
natural convection.

Any enclosure in which the appliance is used shall comply with one of the following:

 An enclosure with walls on all sides, but at least one permanent opening at ground level and no 
overhead cover (see Example 1).
Within a partial enclosure that includes an overhead cover and no more than two walls (see Example 2 
& 3).

Within a partial enclosure that includes an overhead cover and more than two walls, the 

following will apply:

at least 25% of the total wall area is completely open, and

at least 30% of the remaining wall area is open and unrestricted (see Example 4 & 5).
In the case of balconies, at least 20% of the total wall area shall be and remain open and unrestricted.

Gasmate

®

 is a registered trademark of:     Sitro Group Australia Pty Ltd   www.gasmate.com.au 

 

 

             Aber, Hamilton, N.Z   www.gasmate.co.nz

Summary of Contents for Inferno FHIN100 Series

Page 1: ...this equipment FOR OUTDOOR USE ONLY PROPANE GAS FEATURES The ideal solution for extending the season of outdoor entertaining Direct ignition Maximum output 36MJ h Adjustable heat output Operates for approximately 9 hours on a properly filled 9Kg propane cylinder Includes a safety tip over switch that halts supply of gas to the unit should it be accidentally knocked over Flame safeguard system for ...

Page 2: ... qualified service person a The appliance area must be kept clear and free of combustible materials gasoline and other flammable vapours and liquids b Gas orifices and burner must be kept clear of dirt and cobwebs Flow of combustion and ventilation air through the perforated portions of the heater must not be obstructed Cleaning with a soft brush before use and at least every six months is recomme...

Page 3: ... maintained in good condition When the cylinder is not in use be sure to cover it with a dust cap A leak test should be performed with soapy water whenever connecting a new cylinder NEVER use a match to test for leaks 12 The propane cylinder must be turned off whenever the heater is not in use When the heater is to be stored indoors the propane cylinder and the heater must be disconnected and the ...

Page 4: ...s allow for easy transport Weather resistant heat reflector prevents water from entering the combustion zone and reflects heat down Heat exchange tube has a large heat radiating surface A hinged metal door is provided for easy access to the LP gas cylinder The large base ensures good stability Separation Panel Control Knob 1 Thumb Screws M6x12 1 PC M5x12 2 PC AA 1 5V Battery not included ...

Page 5: ... protection material STEP 1 To assemble unit partially open gas chamber door Carefully lift heat reflector until entire heat exchange tube is exposed STEP 2 After heat exchange tube is fully extended rotate counter clockwise until it stops 1 2 ...

Page 6: ...3 4 STEP 3 Fully open gas chamber door Remove knob from door and place on control stem STEP 4 Locate 2 holes to lock heat exchange tube in place Secure with 2 included wing screws 1 Thumb Screws M6x12 1 PC ...

Page 7: ...al rear slot with the vertical upright beam in the cylinder compartment just above the upper most rows of ventilation holes and manoeuvre it into position ensuring that all of the panel cut outs align with the corresponding beams c Attach the panel to the side beams using two wing screws through the bent tabs d Ensure the hose is located into the split rubber grommet DO NOT USE HEATER UNTIL PANEL ...

Page 8: ...Use Only Minimum Clearance from Combustible Surfaces Combustible materials are considered to be wood compressed paper plant fibres plastic or other materials that are capable of being ignited and burned 1800mm Hose connection point 700mm ...

Page 9: ...ts made to product without prior authority from the manufacturer will void any warranty claims Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment LIGHTING INSTRUCTIONS Step 1 Ensure that the control knob is off Slowly open the gas cylinder valve Step 2 Push in control knob and turn anti clockwise to ignite Hold knob in a pulsating ...

Page 10: ...owing An enclosure with walls on all sides but at least one permanent opening at ground level and no overhead cover see Example 1 Within a partial enclosure that includes an overhead cover and no more than two walls see Example 2 3 Within a partial enclosure that includes an overhead cover and more than two walls the following will apply at least 25 of the total wall area is completely open and at...

Reviews: