Installing -electrical connections
A. When making the wire connections, use the entire length of conduit provided.
The conduit must not be shortened.
B. With the cooktop in place, open the front of the cabinet door.
C.Insert the wires from the conduit through the opening of the junction box.
D. Connect the red and black leads from the cooktop conduit to the corresponding
leads in the junction box.
E. Once the connections are made, secure wires together using wire nuts.
Grounding instructions:
The bare ground wire in the conduit is connected to the cooktop frame. Effective
January 1, 1996, the National Electrical Code will not permit grounding through
neutral. If used in new construction after January 1, 1996 or in a mobile home,
recreational vehicle or if local codes do not permit grounding through the neutral
white lead, attach the appliance grounding lead(green or copper) to the residence
grounding conductor (green or bare copper) in accordance with local codes.
When connecting to a 3 conductor branch circuit, if local codes permit, connect
the bare ground connector lead of the cooktop to the branch circuit neutral(gray or
white in color).
Strain Relief Clamp
Black
Red
Ground
Black
Red
Ground wire location
Strain Relief Clamp
Black
Red
Ground
www.gaslandchef.com
3330-A Marathon Ct Charleston, SC 29418
17