background image

Multi Gas Clip Simple Plus User’s Manual

UM MGC-S-PLUS v1.00a 

Portable gas detectors you can count on

18 of 18

Gas Clip Technologies, Inc .

305 W FM 1382   Ste 540

Cedar Hill, TX 75104 USA

Toll Free: 

1 (877) 525-0808

Phone:  

+1 (972) 775-7577

Fax: 

+1 (972) 775-2483

E-mail: [email protected]

Website: www.gascliptech.com

CONTACT INFORMATION

LIMITED WARRANTY

Gas Clip Technologies (“GCT”) warrants this product to be free from defects in material and workmanship under normal use and service for a period of two years beginning 
upon the date of activation for all Multi Gas Clip products. Date of activation allowance is limited to the “Activate before…” date provided on the shipment box label. This 
warranty extends only to the sale of new and unused products to the original buyer. GCT’s warranty obligation is limited, at GCT’s option, to refund of the purchase price, 
repair, or replacement of a defective product that is returned to a GCT authorized service center within the warranty period. In no event shall GCT’s liability hereunder exceed 
the purchase price actually paid by the buyer for the product. This warranty does not include the following: (1) Fuses, disposable batteries, or routine replacement of parts 
due to the normal wear and tear of the product arising from use. (2) Any product which, in GCT’s opinion, has been misused, altered, neglected or damaged by accident 
or abnormal conditions of operation, handling, or use. (3) Any damage or defects attributable to repair of the product by any person other than the authorized dealer, or 
installation of unapproved parts on the product. The obligations set forth in this warranty are conditional on the following: (1) Proper storage, installation, calibration, use, 
maintenance, and compliance with the User’s Manual instructions and any other applicable recommendations of GCT. (2) The buyer promptly notifying GCT of any defect 
and, if required, promptly making the product available for correction. No goods shall be returned to GCT until receipt by the buyer of instructions from GCT. (3) The right 
of GCT to require that the buyer provide proof of sale or packing slip to establish that the product is within the warranty period. The buyer agrees that this warranty is the 
buyer’s sole and exclusive remedy and is in lieu of all other warranties, expressed or implied, including, but not limited to, any implied warranty or merchantability or fitness 
for a particular purpose. GCT shall not be liable for any special, indirect, incidental, or consequential damages or losses, including loss of data, whether arising from breach 
of warranty or based on contract, tort, or reliance on any other theory. Some countries or states do not allow limitation of the term of an applied warranty, or exclusion or 
limitation of incidental or consequential damages. The limitations and exclusions of this warranty may not apply to every buyer. If any provision of this warranty is held 
invalid or unenforceable by a court of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.  

Note: 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of 

the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference when the equipment 

is operated in an industrial environment.  This equipment generates, uses, and can radiate radio frequency energy and, if not 

installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. 

Gas concentration

Accuracy

0.00% CH4

±0.10%

0.25% CH4

±0.15%

0.50% CH4

±0.15%

1.00% CH4

±0.20%

2.00% CH4

±0.20%

3.00% CH4

±0.40%

4.00% CH4

±0.40%

5.00% CH4

±0.50%

Table 1: Accuracy at different gas concentrations

Summary of Contents for Multi Gas Clip Simple Plus

Page 1: ...UM MGC S PLUS v1 00a Portable gas detectors you can count on 1 of 18 Multi Gas Clip Simple Plus G A S C L I P T E C H C O M User s Manual...

Page 2: ...4 Off Mode 4 Alarms 5 Alarm Behavior 5 Default Alarms 5 Detector Menus 6 Main Menu 6 Status Menu 6 Option Menu 7 Adjustable Options 7 Detector Maintenance 9 Battery 9 Bump Testing 9 Manual Bump Test...

Page 3: ...the detector to sensor poisons such as but not limited to alcohol and citrus based products Exposure to poisons may impair the accuracy and or response time of the detector If suspected sensor poisoni...

Page 4: ...Ports 4 O2 Sensor 5 Dual Tox Sensor 6 Audible Alarm Port 7 Display 8 Alarm Bar LEDs 9 Maintenance LEDs 10 Infrared IR Communication Window 11 Alligator Clip with Safety Ring 12 Certification Label 13...

Page 5: ...n Test Mode icon 3 will appear and flash indicating it is time to apply gas The Battery Indicator 4 is displayed as a battery icon which is solid as long as the battery is not low The battery won t ne...

Page 6: ...r the sensor reading while it is stabilizing and being self tested Once all sensors have completed the warm up and stabilization sequence 65 seconds the detector is fully operational and ready to dete...

Page 7: ...ry outline only 20 Minutes remaining single beep flash battery outline only 10 Minutes remaining single beep flash battery outline flashes 5 Minutes remaining continuous beep flash every 5 seconds Exp...

Page 8: ...ill immediately return to normal operation Status Menu The Status Menu is accessed by pressing the Power Menu Button once during the SHOW STATUS prompt The detector will display in the following order...

Page 9: ...is GAS CLIP TECHNOLOGIES Alarm Limits This option allows you to set sensor low and high alarm limits Each sensor contains separate alarm threshold values that tell the detector when to go into alarm...

Page 10: ...be adjusted only with the GCT IR Link by Volume CH4 Allows the detector to display gas readings as by volume CH4 rather than LEL The conversion rate can be configured by specifying what the methane co...

Page 11: ...nual Bump Test Instructions Press the Power Menu Button two separate times in quick succession double tap to access the Main Menu The display will then show in the following order When the screen disp...

Page 12: ...MGC S Calibration Cap and the detector will return to normal operation after a short period of time The bump due date will be automatically reset based on the new bump date The bump test will be recor...

Page 13: ...failed a bump test be used During a manual bump test the audible visual vibrating prompting to apply gas will continue for approximately two minutes If gas is not applied within the two minutes then...

Page 14: ...is detected and as the detector adjusts the calibration parameters Once calibration is complete the detector will display the next calibration date before returning to normal alarming operation If a...

Page 15: ...first bump test and so on Bump tests are differentiated from normal events when the alarm condition occurs inside of an MGC Simple Clip Dock or when the detector is manually bump tested according to t...

Page 16: ...ndow lined up approximately 2 3 inches apart 1 Open GCT IR Link Software downloaded for free from www gascliptech com under Resources tab 2 Click on Download Logs icon at the top left corner 3 Select...

Page 17: ...MGC S CSK Hard sided Carrying Case with Foam Insert 1 ft Sampling Probe Air Stone Particulate Filter MGC S Calibration Cap 10 ft Sampling Hose and 3 ft Calibration Test Hose with Quick Connect Hand A...

Page 18: ...ox Sensor P N MGC SE 4DT O2 Sensor P N MGC SE O2 Replacement Filters Filter Pack of 10 P N MGC S FILTER 10 Filter Pack of 2 P N MGC S FILTER 2 Various authorized replacement spare parts for Multi Gas...

Page 19: ...ge Resolution Accuracy T90 H2S 0 100 ppm 0 1 2 ppm 30s CO 0 500 ppm 1 5 ppm 30s Combustible 0 100 LEL 0 1 See Table 1 page 18 30s O2 0 30 vol 0 1 0 7 vol 15s Sensor Type H2S CO O2 Single plug in elect...

Page 20: ...s and any other applicable recommendations of GCT 2 The buyer promptly notifying GCT of any defect and if required promptly making the product available for correction No goods shall be returned to GC...

Reviews: