background image

 

MGC Dock 

User’s Manual

 

V1.5 

Port able gas det ect or s y ou can count  on.  

5 of 15 

 

Basic Operation 

Clip Dock Components 

 

1

2

3

6

8

9

10

4

5

11

7

 

 

 

 

LEDs 

LED 

Color 

Description 

Unit LEDs 

orange 

t est  in progress 

red 

t est  failed 

green 

t est  passed 

orange cycling 

charging 

Power LED 

green 

pow er ed on  

green blinking 

low  bat t ery  

orange 

t est  in progress 

orange blinking 

No USB m em ory det ect ed*  

*  The Clip Dock will be unable t o r ecor d t est  r esult s if USB m em or y is not  inst alled 

Entry 

Description 

Det ect or  Bay 

Access Hat ch Screw s ( x2)  

Pressure Gauge 

Gas Bot t le 

USB Mem ory St ick  

Unit  LED ( x4)  

Power LED 

But t ons 

Charging Port  

10 

Exhaust  Port  

11 

Solenoid, Regulat or, Gauge 

12 

( Opt ional)  Gas I nlet  

Summary of Contents for Clip Dock

Page 1: ...User s Manual...

Page 2: ...User Operation 6 Turning the Clip Dock On and Off 6 Charging 6 Calibration Gas Installation 6 Button Usage 6 Troubleshooting Failures 7 Clip Dock Configuration 8 Clip Dock Options 8 Detector Options 8...

Page 3: ...Clip Dock contains a lithium battery that must be disposed of by a qualified recycler Check local regulations for proper disposal Warning The battery may present a fire or chemical burn hazard if mis...

Page 4: ...can be optionally housed in a rugged Pelican case or a wall mountable m etal enclosure Logs are stored on a USB flash drive which can easily be transferred to a computer for analysis Each Clip Dock co...

Page 5: ...cling charging Power LED green powered on green blinking low battery orange test in progress orange blinking No USB mem ory detected The Clip Dock will be unable to record test results if USB memory i...

Page 6: ...the bottle contains four gases so that any detector model can be tested The GCT Manager software allows you to specify the gas concentrations The default concentration is set for a mix of all gas type...

Page 7: ...eeper cavities and clear any obstructions 2 Clean the small IR com munication window located on the top of the detector 3 Verify the gas bottle is not empty 58L bottles are full at 500 PSI 116L at 100...

Page 8: ...to the PC offers faster transfers or configuration without a GCT IR Link Clip Dock Options The software program will provide a detailed description of each option if the mouse is hovered of it The Lo...

Page 9: ...fail test result Firmware and Hardware versions Location optional user string that can be configured with the GCT Manager Line 2 Bay test results for the inserted detector Bay Number 1 4 Detector Mod...

Page 10: ...on Line 2 User Message Language TWA m ethod TWA and STEL intervals SAFE mode T F Self Test Lock T F Auto Zero T F Maintenance Notification T F Dock Lock T F Latching Alarms T F The following MGC Senso...

Page 11: ...all anchors should be used For installation on brick or m etal structures the user will have to supply suitable mounting hardware A convenient wall mounting template is included to help locate the mou...

Page 12: ...ck case to slide over the screw 4 Hang the Clip Dock on the top two screws 5 Open the gas cylinder compartm ent and screw in the remaining two screws 6 To complete the installation Lead the exhaust tu...

Page 13: ...emovable USB memory Warranty Full 2 years User Options Location Gas expiration date Gas bottle lot number gas concentrations bump gas time bump sensor pass criteria calibrations bump tests hibernation...

Page 14: ...etectors you can count on 14 of 15 Contact Information Gas Clip Technologies Inc 610 Uptown Blvd Suite 4100 Cedar Hill TX 75104 Toll Free 877 525 0808 Phone 972 775 7577 Fax 972 775 2483 E mail info g...

Page 15: ...l on 1 Proper storage installation use maintenance and compliance with the user s manual instructions and any other applicable recommendations of GCT 2 The buyer promptly notifying GCT of any defect a...