2.2 Product 

Description

The Magnum P62F-Series Ethernet “Outdoor” Switches are designed to operate in

abnormal temperature applications, and are suitable for use in environments with inhospitable

high / low temperatures. Each Magnum P62F Ethernet switch provides two built-in 100Mb full-

duplex switched fiber ports so that several units can be daisy-chained, coupled with the

convenience of six switched 10/100Mb copper (RJ45) ports for easy connectivity to local nodes

and devices, all in one compact rugged unit.

The two “future-proof” fiber ports have been designed with full-duplex 100Mbps

switched fiber port, and six copper (RJ-45) with full / half-duplex-10/100-auto-negotiating ports.

The Magnum P62F-Series Ethernet Switches provide the switching speed and the reliability to

smoothly support multiple workgroups at 100Mbps or 10Mbps speed. The optional fiber ports

are normally configured and tested with the Magnum P62F unit in the factory, and available in

multi-mode and single-mode SC-type fiber connectors.

Designed specifically to operate in temperature 

un

controlled applications, the P62F’s

high strength steel case functions as a heat sink to draw away the heat from the internal

electronics and dissipate it. The efficient design of P62F case can easily handle the unusual heat

of  

70

°°°°

C (160

°°°°

F)

 and extreme cold of -

40

°°°°

C (-40

°°°°

F)

. when properly installed (see Sec. 3.0).

Applications for Magnum P62F-Series Switches include roadside traffic data

collection and control stations, unheated and or high temperatures locations, plenums and ceiling

locations in commercial buildings, data communications huts and pedestals, and military  sites.

A Magnum P62F Ethernet Switch is easy to install and use. Addresses of attached

nodes are automatically learned and maintained, adapting the switching services to network

changes and expansions. Top-mounted LEDs provide extra advantage to the user to observe

status information of each port. The Magnum P62F-Series Ethernet Switches generate high

performance plug-and-play operation in a rugged package. The high-strength steel enclosure

gives extra protection.

Each P62F Ethernet Switch is non-blocking on all ports and has 1MB packet buffers

and a 16K-node address table for advanced performance. A Magnum P62F Ethernet Switch,

armed with store-and-forward switching ability, filters all faulty packets to minimize traffic

congestion.

Summary of Contents for Magnum P62F Series

Page 1: ...ttCom com www GarrettCom com Corporate Headquarters GarrettCom Inc 213 Hammond Avenue Fremont CA 94539 Phone 510 438 9071 Fax 510 438 9072 Web www GarrettCom com Email support Garrettcom com Magnum P6...

Page 2: ......

Page 3: ...witch are trademarks and Personal Hub is a registered trademark of GarrettCom Inc Important The Magnum P62F Series Ethernet Switches contains no user serviceable parts Attempted service by unauthorize...

Page 4: ...ate frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found...

Page 5: ...d Media Fiber Hub 16 port Stackable 10 100 auto sensing Dual Speed 8 port and 16 port Stackables 10 100 auto sensing Stackable Hubs SNMP Optional 10Mb series and 100Mb series both with optional port m...

Page 6: ......

Page 7: ...de 16 3 2 5 Power budget Calculation for P62F Fiber media 17 3 2 6 Connecting to NICs which support Auto Negotiation 18 3 3 Powering the Magnum P62F Series Switches 18 3 3 1 Powering the Magnum P62F 4...

Page 8: ...not including packet time 100 to 10 Mbps 5 s 10 to 100Mbps 5 s Path Delay Value 50 BT on all ports Maximum Ethernet Segment or Domain Lengths 10BASE T Unshielded twisted pair 100 m 328 ft 100BASE TX C...

Page 9: ...plate included Suitable for stand alone shelf pedestal or wall mounting The case also serves as a heat sink The metal mounting base is included 13 guage steel Without the base the box size is only 7...

Page 10: ...45 and no fiber ports Has 16KB address table and 1 0MB packet buffers AC power input 85 260vac 47 63Hz worldwide auto ranging via PSX A Power Source Extended Temp a separate unit Steel case used as a...

Page 11: ...agnum P62F 5V NOF Same as P62F NOF except with 5VFC input via PSX A using military type screw lock connectors Magnum PSX 5V CBL spare 2 ft power cord with military type screw lock connector spare for...

Page 12: ...nstallation and User Guide 1 Product Registration Card Optional if AC power 1 PSX A Power Source Extended Temp unit 1 6 ft long AC Power chord for PSX A Unit only Optional PSX T 125 VDC 1 PSX T Power...

Page 13: ...operate in temperature uncontrolled applications the P62F s high strength steel case functions as a heat sink to draw away the heat from the internal electronics and dissipate it The efficient design...

Page 14: ...rs The fiber ports 1 and 8 have LK ACT indicators The rugged design of the case using high strength rugged 18 gauge steel enables this product to withstand environments with inhospitable high low temp...

Page 15: ...dicates the port is transmitting receiving The 10 100 LED is ON for 100Mbps and OFF for 10 Mbps when LINK is made For fiber ports the LEDs are the same except no F H and 10Mb is not possible A device...

Page 16: ...internally to provide maximum network performance with the least dropped packets When the P62F Switch detects that its free buffer queue space is low the Switch sends industry standard full duplex on...

Page 17: ...are on the top of the unit for easy viewing in any situation As the units are normally vertical for wall or pedestal mounting top surface viewing is most convenient Installation is Plug and Play opera...

Page 18: ...Switch serves this requirement economically and efficiently The six full and half duplex switched ports make the required setup simple for collection of traffic data The uncontrolled outdoor temperatu...

Page 19: ...the temperature controlled packaging to provide an exceptional Ethernet product Figure 2 6 2 Three P62F connects together to provide 10 Mbps and100Mbps network with Fast Ethernet backbone In this exam...

Page 20: ...P62F unit Maintain an open view of the top surface to visually monitor the status LEDs 3 1 1 Table Top or Shelf Mounting The Magnum P62F Ethernet switch can be easily mounted on a table top shelf or a...

Page 21: ...per wiring Media IEEE Standard Connector Twisted Pair CAT 3 or 5 10BASE T RJ 45 Twisted Pair CAT 5 100BASE TX RJ 45 Fiber Multi mode 100BASE FX SC Fiber Single mode 100BASE FX SC NOTE It is recommende...

Page 22: ...of the duplex fiber optic cable may be coded using color bands at regular intervals you should use the color coded strand on the associated ports at each end of the fiber optic cable segment 3 Connec...

Page 23: ...2 8 dB km and the Cable Loss for 100 140 Multi mode is 3 3 dB km and the Cable Loss for 9 125 Single mode is 0 5 dB km The following data has been collected from component manufacturer s HP s and Siem...

Page 24: ...igh reliability record DC Power Terminals internally floating GND Terminal for earth or ground wire connection to the P62F chassis Input Voltage 20 to 70 VDC Input current 0 7 amp max Power Consumptio...

Page 25: ...to the P62F 5V Switch Input Voltage 85 264 VAC 47 63HZ Auto ranging AC Power Connector IEC type male recessed Power Output 5VDC 3Amps max Input Fuse for overload and short protection 3AG type 0 5 Amp...

Page 26: ...ew down lead posts covered by a removable safety shield or cover The power terminals are identified as positive and negative and they are floating inside the unit so that either may be grounded by the...

Page 27: ...ef feature provided as part of the package design The Magnum P62F Series Switches have a tie wrap holder as part of the base plate of the unit for use for cable strain relief The strain relief feature...

Page 28: ...by auto negotiation to full or half duplex as the unit attached with these ports The internal functions of P62F is described below Switching Filtering and Forwarding Each time a packet arrives on one...

Page 29: ...ides will agree to the speed being used Depending upon the device connected this will result in agreement to operate at either 10 Mbps or 100Mbps speed When the LK ACT LED is ON steady ON indicates LI...

Page 30: ...stallation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure that they h...

Page 31: ...s workstations terminals and printers plus the various network media types being used 4 A record of changes that have been made to your network configuration prior to the occurrence of the problem Any...

Page 32: ...he unit in Styrofoam popcorn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shi...

Reviews: