Magnum 6KM Mobile Ethernet Switch Installation and User Guide
07/10
35
www GarrettCom com
.
.
APPENDIX B: DC Single Source Power Input
(Power Input installation to be performed by a certified electrician)
B1.0
Specifications for Magnum 6KM Switches, DC Power at 12, 24,
–48, 110, 125 and 250VDC Power input
Each
Magnum Model 6KM Managed Switch requires DC power input, at 12,
24, 48, 110, 125 and 250VDC nominal. The wide range of DC power input types
qualifies this product for use in 12, 24, 48, 110, 125 and 250VDC applications in
different industries.
DC Power Terminals
: “+”, “
-
”
are
internally floating so that user may ground either
GND
: ground wire connection to the 6KM
chassis (#6-32 thread)
Fig B1.0a Location of chassis ground
Power Consumption:
15 watts typical (for a fully loaded fiber model with 2Gb)
10 watts typical (for 8 ports, copper and 100Mb fiber)
12VDC Power Input nominal (range 10 to 15VDC)
24VDC Power Input nominal (range 18 to 36VDC)
-48VDC Power Input nominal (range 36 to 60VDC)
110VDC Power Input nominal (range 77 to 137VDC)
125VDC Power Input nominal (range 88 to 150VDC)
250VDC Power Input nominal (range 160 to 300VDC)