Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
27
www GarrettCom com
.
.
Fig 3.3 - Magnum 6K8 mounted
vertically with DIN-Rail brackets and
latches
The DIN-Rail mounting brackets
and latches are optional and need to be
ordered as separate items, e.g Model # DIN-
RAIL-6K8
3.3.1 Installing
DIN-RAIL
variable brackets on
Magnum 6K8
Magnum 6K8 Din-Rail kit comes along
with the following-
BOM:
Item
Quantity Description
1
1
DIN Rail Clip assy
2
2
#10-32 x ¼ Phillip
Flat head screws with
undercut
3
8
#4-40 x 3/8 Phillip Flat head screw
Din-Rail kit Installation procedures:
1. Remove the back plate from Magnum 6K8 UNIT
a. There are eight screws along the edge of the unit to remove.
b.. Do not re-use the old screws.
2. On the back-plate
a. Locate the indented side with 1, 11……
b. “1” indentation signify center of the mounted Din-Rail clip
location.
c. Each indented locations (1-11-111…) are ½ inches apart from the center.
Fig 1.
3.
Select the height position via
indented side marking .
4. Place the
DIN Rail Clip
assembly under indented side of
the plate. Place two of the screws,
came along the kit (#10-32 x ¼
Phillip Flat head screws with
undercut) onto the indented side
and screw tight the assembly as
shown in Fig 2a.
Note: Make sure the screws must
have the 5lbs/in torque minimum.