background image

Magnum 6K32 Managed Switch            Installation and User Guide (02/05)

 

 

35 

www  GarrettCom  com

.

.

 

Address Learning 

 

All

 

Magnum 6K32 units have address table capacities of 4K node addresses 

suitable for use in larger networks. They are self-learning, so as nodes are added, 

removed or moved from one segment to another, the 6K32 Switch automatically keeps 

up with node locations.   

An address-aging algorithm causes least-used addresses to fall out in favor of 

frequently-used addresses.  To reset the address buffer, cycle power down-and-up. 

 

 

4.2 Status 

LEDs 

For all Magnum 6K32 models : 

PWR          :  

Power LED, ON when external power is applied to the unit.  

 

LK             :  

 Steady ON, Link status for 10 Mbps and 100Mbps operation.  

 

ACT          :  

ON with port activity for 10 Mbps and 100Mbps operation.  

 

F/H            : 

Full / Half duplex LED,  ON when the port is running full 
duplex, OFF for half duplex.  

100/10        : 

Speed LED, ON when the speed is 100Mbps , OFF when the     

speed is 10 Mbps 

 

 

4.3 

Up-link Cross-over Switch on RJ-45 port modules, for port#1 only 

The modular slot provided on Magnum 6K32 managed switch can be filled 

with 6KP8-RJ45 port module among all the multiple choices of port modules. The upper 

part of the copper port module (6KP8-RJ45) has a manual Up-link switch, located on the 

inside of the unit on the port module board next to the RJ45 port # 1 which it controls.  It 

enables the port’s cable to be cascaded (X) to a 10/100Mb repeater or switching hub in 

the network. The manual Up-link switch position is configured as (=) position as default 

factory setting, where used for all-copper module or combo modules.

 

 

4.4 

Auto-Cross (MDIX)Auto-negotiation, for 10/100Mbps RJ-45 ports

 

 

The 24 RJ-45 ports on Magnum 6K32 supports auto-cross (MDI or MDIX) in the 

auto-negotiation mode according to the IEEE 802.3u standard.  No crossover cables 

are needed when connecting the 6K32’s 10/100 copper ports to other unmanaged 

switches, legacy hubs, managed switches, media-converters etc.  Please note that 

there can be conditions with managed switches where the switch manager fixes the 

port settings via software, and the result of the auto-negotiation is changed in the 

managed switch by the manager commands. In such cases, the 10/100 speed or the 

F/H mode may be affected, but auto-cross in the 6K32 Switches will still work. The 

auto-cross function can be disabled, if fixed the port at 10 or 100Mb through 

software..

 

Summary of Contents for Magnum 6K32

Page 1: ...Corporate Headquarters GarrettCom Inc 47823 Westinghouse Drive Fremont CA 94539 Phone 510 438 9071 Fax 510 438 9072 Website http www GarrettCom com email support garrettcom com Magnum 6K32 Managed Swi...

Page 2: ...sonal Hub is a registered trademark of GarrettCom Inc GarrettCom Inc reserves the right to change specifications performance characteristics and or model offerings without notice Important The Magnum...

Page 3: ...e to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules which are desi...

Page 4: ...ng Fiber Optic ST type twist lock 21 3 2 2 Connecting Fiber Optic SC type Snap In 21 3 2 3 Connecting Single Mode Fiber Optic 22 3 2 4 Connecting Twisted Pair 22 3 2 5 Connecting Twisted Pair 22 3 3 T...

Page 5: ...Small Form Factor 46 5 2 8 6KP8 45LC Combo factor and RJ 45 Connector 47 5 2 9 6KP8 RJ45 Twisted Pair 10 100Mb 8 Port 47 5 2 10 6KP8 45 2MT multi mode FX MTRJ Small Form Factor 48 5 2 10a 6KP8 45 2LC...

Page 6: ...orts mixed speed and mixed media types full switching performance Outdoor Ethernet Switches for temperature uncontrolled locations 6 10 100 and 2 100Mb fiber ports can be connected in strings and ring...

Page 7: ...Spanning tree protocol IEEE 802 1w Rapid Spanning tree protocol IEEE 802 1q VLAN Tagging IEEE 802 3x Flow Control IEEE 802 3ad Link Aggregation Trunking Maximum 10 Mbps Ethernet Segment Lengths Unshi...

Page 8: ...0in H x 17 0in W x 9 0in D 4 32cm H x 43 2cm W x 22 9cm D Cooling method Fan cooled 3 7 cfm ea Management Console connector DB 9 for RS 232 null modem cable sometimes called an X modem cable Power Sup...

Page 9: ...1 located next to the port internally Note Other port specific user settings such as FDX or HDX AUTO OFF copper 10 100 speed can be configured using software commands Agency Approvals UL listed UL195...

Page 10: ...2R except the power input is 24VDC Magnum 6K32 125VDC Same as 6K32 except the power input is 125VDC Magnum 6K32R 125VDC Same as 6K32R except the power input is 125VDC Configuration Options Each Magnum...

Page 11: ...ceiver module for use in GBPM xOTX One 1000BASE LX LH port with 1310nm single mode SC 25km fiber connector GBIC LXSC40 GBIC transceiver module for use in GBPM xOTX One 1000BASE ZX port with 1550nm sin...

Page 12: ...port module option in modular slot 1 AC Power Cord U S and other 115 VAC only 1 Set of metal Ears for 19 rack mounting 1 Installation and User Guide this manual 1 Product Registration Card Remove the...

Page 13: ...flexibility is achieved via a family of 6K port modules for copper and fiber built in emphasizing Small Form Factor fiber for high fiber port density 6 port modules for fiber and RJ 45 combinations a...

Page 14: ...ed in the field See Section 5 Status LEDs are part of each port module and are viewable when connecting the Ethernet media A regular rack Figure 2 2 1a 6K32 front view configured for 24 RJ 45 ports 1...

Page 15: ...lf duplex mode per port through set up of the software See Magnum 6K32 MNS Software Manual for the flexibility to adapt to any FDX or HDX type of Fast Ethernet devices There are three LED s per fiber...

Page 16: ...d The FDX HDX LED is ON to indicate full duplex operation and OFF to indicate half duplex mode A twisted pair cable must be connected into an RJ 45 port and the Link LK indicator for that port must be...

Page 17: ...and with 4 RJ45 10 100 copper and 2 10Mb fiber mm ST ports The 4 RJ 45 2 10 Mb ST operation of the SFF fiber and the RJ 45 half of the module is as described for those port types above For detailed in...

Page 18: ...well with new models appearing often The 1000Mb Gigabit fiber port modules on the Magnum 6K32 are normally set factory default to operate at AUTO mode for best fiber distance and performance The 1000M...

Page 19: ...ough technique permits collision fragment frames which are a result of late collisions to be forwarded which add to the network traffic Since there is no way to filter frames with a bad CRC the entire...

Page 20: ...Magnum MNS 6K Software User guide in pdf format a separate document normally accessed via the web browser ftp ftp garrettcom com or FTP client program by ftp GarrettCom com using user m6kuser passwor...

Page 21: ...amily to choose from The port modules are normally factory installed and tested but may be changed in the field Rack mounting may be standard or reverse 19 inch or ETSI or 23 Telco The standard rack m...

Page 22: ...itch for a VLAN application Equipped with lots of advanced management features the Magnum 6K32 Managed switch is able to handle a VLAN application and provide security and performance in an Ethernet n...

Page 23: ...building The entire spread network is managed to provide easy detectable uninterrupted support through a viewable SNMP monitor The Magnum 6K32 Managed Switch equipped with copper and optional dual Gi...

Page 24: ...RETT Magnum QS5116 PW Managed Fiber Switch Magnum 6K32 1 3 5 10 100 LK F H ACT 10 100 LK 2 4 6 F H AC 1 3 5 10 100 LK F H ACT 10 100 LK 2 4 6 F H AC 1 3 5 10 100 LK F H ACT 10 100 LK 2 4 6 F H AC Data...

Page 25: ...LK 2 4 6 8 F H AC T Magnum QS5116 Fiber Switch GARRET T Magnum QS5116 PW R Managed Fiber Switch Magnum 6K32 1 3 5 7 10 10 0 LK F H AC T 10 10 0 LK 2 4 6 8 F H AC T 1 3 5 7 10 10 0 LK F H AC T 10 10 0...

Page 26: ...6K32 Switches The location of a Magnum 6K32 Switch is dependent on the physical layout of the network Typically the Switch is placed in a central wiring location where groups of network devices need...

Page 27: ...dual connectors with a soft cloth or lint free lens tissue dampened in alcohol Make certain the connectors are clean before connecting Note One strand of the duplex fiber optic cable is coded using c...

Page 28: ...It is recommended that high quality CAT 5 cables which work for both 10 Mb and 100Mb be used whenever possible in order to provide flexibility in a mixed speed network since dual speed ports are auto...

Page 29: ...Manageable Switches can be easily mounted on a table top or any suitable horizontal surface and has four rubber feet to provide stability without scratching finished surfaces 3 3 1 Rack mounting for...

Page 30: ...tus LEDs in the front The status LEDs that are co incident with the ports are still present there and a second or dual set of LEDs are used for status visibility in the front of the unit showing the s...

Page 31: ...d power cord is supplied with each unit shipped within the United States and Canada The auto ranging power supply supports installation environments where the AC voltage is from 90 to 260 volts with a...

Page 32: ...board inside of the 6K32 This provides a Hardware Alarm because the NC contacts will open when internal power is lost either from an external power down condition or by the failure of the power suppl...

Page 33: ...hing Daughter and Granddaughter board The copper 6KPM card should not work properly if mixed with other Fiber combo 6KPM card packages Always install the PM module separately one by one to avoid the m...

Page 34: ...tion spaces and female latch white connectors provided on the far right side of main board along with four stand off s for 6KPM card position See Figure 3 5 1c Figure 3 5 1c Magnum 6K32 s modular slot...

Page 35: ...stalling 6KPM Cards in the Magnum 6K32 Up to four front mounted 6KPM cards may be installed in one Magnum 6K32 Managed Switch unit Follow these steps to install a 6KPM Step 1 Remove top chassis cover...

Page 36: ...aughter Bd and the mating connector being matched to lockup properly Step 4 Hold the daughter board with both hands at the end and align the two cream color latching connectors male placed at the bott...

Page 37: ...y the front panel screen plates come along with the 6K module need to be properly placed on the front of the chassis cover to complete the installation process Step 8 Once the 6KPM cards have been ins...

Page 38: ...ar the latch up connectors as shown in Fig 3 5 3b If the now empty slot is to remain unused be sure to install a 6KPM BLNK face plate cover Figure 3 5 3b Removing a 6KPM Card Follow the step 8 to comp...

Page 39: ...Port is on the Rear of Reverse 6K32 Models Note For detail description of Managed Network Software MNS 6K and Magnum 6K32 Switch configuration for Network Management please refer to Magnum 6K32 Softwa...

Page 40: ...ces There is no software configuring necessary to be done for basic operation at installation or for maintenance The only hardware configuration settings are user options for an UP LINK Switch resides...

Page 41: ...rt module among all the multiple choices of port modules The upper part of the copper port module 6KP8 RJ45 has a manual Up link switch located on the inside of the unit on the port module board next...

Page 42: ...ast Ethernet media converters mostly do not support auto negotiation properly and require that the switched port to which they are connected be at 100Mb fixed speed Attachment to 10 100 auto negotiati...

Page 43: ...ontrol is to reduce the risk of data loss if a long burst of activity causes the switch to save frames until its buffer memory is full This is most likely to occur when data is moving from a 100Mb por...

Page 44: ...5 Single mode is 0 2 dB km LXSC70 The following data has been collected from component manufacturer s Agilent s and Lucent web sites and catalogs to provide guidance to network designers and installer...

Page 45: ...6K32 Managed Switch Port Modules This chapter describes each Port Module PM including appearance functionality and status displays 5 1 Inspecting the Package and Product This section applies only to...

Page 46: ...RJMST 4 10 100Mbps RJ 45 and 2 100Mb multi mode FX ST twist lock Combo Module The Magnum 6KP6 RJMST is a combo 6 port module of RJ 45 s at 10 100Mbps and fiber optic ports at 100MB The Combo module i...

Page 47: ...s an Activity ACT LED indicating packets being received a Link LK LED that indicates proper connectivity with the remote device when lit and FDX HDX LED to indicate full duplex mode when lit or half d...

Page 48: ...orts Whereas the 100Mb ST module allow to connect the 100Mb demand of Switch devices It supports distances according to the 10Base FL standard i e 2Km distance for multi mode fiber Single mode for 10K...

Page 49: ...5 Each port has an Activity ACT LED indicating packets being received a Link LK LED that indicates proper connectivity with the remote device when lit and a FDX HDX LED to indicate full duplex mode w...

Page 50: ...nector The Magnum 6KP6 RJ10ST is also a Combo module equipped with 4 dual speed copper ports and 2 multi mode 10 Mb fiber ST type connectors It provides a combination of copper and Fiber functions in...

Page 51: ...10Mb Multi mode ST Fiber port The 6KP6 RJ10ST is a combo module with two different kinds of fiber flavor with two different speeds The top four ports of MTRJ Small form factor fiber support at 100Mb f...

Page 52: ...nks When installed in a Magnum 6K32 Switch it supports fiber optic cable distances up to the IEEE standard 100Mbps distance limits i e typically 2km at full duplex and 412m at half duplex The compact...

Page 53: ...RJ45 Twisted Pair 10 100Mb 8 Port The 6KP8 RJ45 module supports Ethernet twisted pair segments of any standard length It is equipped with an eight port RJ 45 connector and offers 10 100 full half dupl...

Page 54: ...e 6KP8 RJ45 Crossover Switch Inside is set for by default from the factory for the Port 1 and act similar as other user port The location of crosss over switch can be seen in the fig 3 5 2 c RJ 45 mod...

Page 55: ...the IEEE 802 3z standard 1000Mbps distance limits i e 550m at full duplex 1 1000Mb Fiber SC 4 10 100Mb The GBIC transceiver has been offered in the modular slot with multiple options as per the user...

Page 56: ...shown below in the above figure Each port has an Activity ACT LED indicating packets being received and a link LK LED indicating proper connectivity with the remote device when lit 5 2 12 6KM BLNK Th...

Page 57: ...d to each Magnum 6K32 Switch unit Be certain that each AC power cord is plugged into a functioning electrical outlet Use the PWR LEDs to verify each unit is receiving power 4 If the problem is isolate...

Page 58: ...number http www garrettcom com techsupport RMA rma htm Or call GarrettCom Customer Service at 510 438 9071 during business hours in California or email to support garrettcom com When calling please h...

Page 59: ...ttn Customer Service APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants its products to be free from defects in materials and workmanship for a period of three 3 years from the date of shipment b...

Page 60: ...correctly applied to the two inputs It protects the Switch from incorrect DC input connections An incorrect polarity connection for example will neither affect the Switch its internal power supply nor...

Page 61: ...dure is very straightforward Simply connect the leads to the Magnum unit beginning with ground Ensure that each lead is securely tightened Note The GND should be hooked up first The 6K32 unit has a fl...

Page 62: ...NG INFORMATION To order the optional 48VDC power supply factory installed add a suffix of 48VDC after the product s standard model Example Magnum 6K32R 48VDC Similarly to order the optional 24VDC or 1...

Page 63: ...s Dual Source option are identical to those listed in the Magnum 6K32 Fiber Switches Installation and User Guide including Appendix B Internal DC Power Supply Option C2 0 MAGNUM 6K32 with 48VDC 24VDC...

Page 64: ...the Magnum 6Ks Switch shown in Figure The 48VDC terminal block on the Magnum 6K32 Switch as shown in Fig C5 0 is located on the right rear of the unit and is equipped with five 5 screw down lead posts...

Page 65: ...he cable to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block C6 0 ORDERING INFORMATION To order the optional Dual Source 48VDC power supply factory ins...

Reviews: