Magnum 6K32 Managed Switch Installation and User Guide (02/05)
2
www GarrettCom com
.
.
Fiber connector types supported:
ST-type
(twist-lock)
SC-type
(snap-in)
MTRJ-type Small Form Factor (SFF)
LC-type Small Form Factor (SFF)
GBIC
modules
LEDs: Per Port
LK:
Steady ON when media link is operational
ACT:
ON with receiver port activity
FDX/HDX:
ON = Full-Duplex Mode
OFF = Half-Duplex Mode
100/10:
ON = 100Mbps speed
OFF = 10 Mbps
Operating
Environment
Ambient Temperature: 25
°
to 130
°
F (-5
°
to 55
°
C)
Storage Temperature: -40
°
to 185
°
F (-40
°
to 85
°
C)
Ambient Relative Humidity: 5% to 95% (non-condensing)
Altitude: -200 to 13,000 ft. (-60 to 4000m)
Conformal Coating option: Request quote
Packaging
Enclosure: Rugged High strength metal. Suitable for stand-alone
or rack-mounting
Dimensions: 1.70in. H x 17.0in. W x 9.0in. D
4.32cm H x 43.2cm W x 22.9cm D
Cooling method: Fan cooled, @ 3@ 7 cfm ea.
Management Console connector
DB-9 for RS-232 “ null-modem “ cable (sometimes called an X-modem cable)
Power Supply (Internal)
AC Power Connector: IEC-type, male recessed at rear of chassis,
with adjacent manual ON-OFF switch (optional if no Alarms Cont.)
Input Voltage: 100 to 240 VAC (auto-ranging)
Input Frequency: 47 to 63 Hz (auto-ranging)
Power Consumption: 45 watts max (with fiber module)
30 watts for a fully-loaded copper only model
DC Power Supply (Options)
-48VDC Power
Input Voltage : -36 to -70 VDC
24VDC Power
Input Voltage : 20 to 40VDC
125VDC Power and 100VDC
Input Voltage : 88 to 150VDC
Std. Terminal Block : “ -, GND, + ”
Power Consumption: same as for AC models, see above
For (
Optional
) DC internal power supplies at –48VDC, 24VDC and 125VDC,
including Dual Source options (
for continuity of operation when either of the DC
input sources are interrupted)
, see Appendices B and C.