![Garrett MAGNASCANNER CS 5000 Owner'S Manual Download Page 44](http://html1.mh-extra.com/html/garrett/magnascanner-cs-5000/magnascanner-cs-5000_owners-manual_3673852044.webp)
41
MAGNASCANNER CS 5000
OWNERS MANUAL
' 2000 GARRETT METAL DETECTORS, INC.
4/30/00
PN 11674XX
Revised
11.6.
BATTERY BACK-UP MODULE (OPTIONAL)
This optional module is a field-installable assembly that provides power to operate the
Magnascanner CS 5000 for up to twenty (20) hours on a fully charged battery. System
software includes an alarm feature that alerts the operator to a low-battery condition.
This ensures that the unit continues to operate at its peak performance level.
A switch is provided on the side of the battery module to fully disconnect battery power.
This switch whould be set to its OFF position anytime the system is being stored and
anytime the system is not in use and is not connected to AC power for more than 24
hours. Standby circuitry will discharge a fully charged set of batteries in about ten (10)
to fifteen (15) days whenever the switch is not turned off.
11.6.1.
INSTALLATION
1. Open the access door of the detection unit;
2. Disconnect the AC power plug from the Power Supply Module;
3. Remove the three (3) screws that hold the Controller Module Cover;
4. Remove the four (4) acorn nuts that are attached to the Battery Pack Module mount-
ing studs;
5. Install the Battery Pack Module and replace the acorn nuts;
6. Disconnect the Power Supply Module connector on the upper left of the Controller
Circuit Board;
7. Reconnect the Power Supply Module and Battery Pack Module as shown;
8. Reassemble the system and test.