Garrecht Avionik GmbH
VT-01 Transponder
Installation Manual - english -
Document:
01.0200.11E
Revision: 1.3
12
5.7.2. VT-01 UltraCompact
Section
Category
Conditions
Temperature / Altitude D1
4.0
D1
Low ground survival temperature
4.5.1
D1
-55°C
Low operating temperature
4.5.1
D1
-20°C
High ground survival Temperature
4.5.2
D1
+85°C
High Short-time Operating Temperature
4.5.2
D1
+70°C
High Operating Temperature
4.5.3
D1
+55°C
In .Flight Loss of Cooling
4.5.4
Z
No auxiliary cooling required
Altitude
4.6.1
D1
50.000 ft.*
Temperature Variation
5.0
B
5°C / minute
Humidity
6.0
A
Shock
7.0
B
6 G operational shocks
20 G crash safety
Vibration
8.0
U2
R
Vibration curve F/F1
Vibration curve B/B1
Explosion Profness
9.0
X
Water Profness
10.0
X
Fluids Susceptibilities
11.0
X
Sand and Dust
12.0
X
Fungus Resistance
13.0
X
Salt Spray
14.0
X
Magnetic Effect
15.0
Z
Less than 0.3 m
Power Input (DC)
16.0
B
Voltage Spike Conducted
17.0
B
Audio Frequency Conducted Susceptibility
18.0
B
Induced Signal Susceptibility
19.0
A
Radio Frequency Susceptibility
20.0
S
T
radiated susc.
conducted susc.
Emission of RF
21.0
B
compliant with CAT M except
of harmonics of 1090 MHz
Lightning Induced Transient Susceptibility
22.0
A2XXX
Lightning Direct Effects
23.0
X
Icing
24.0
X
Electrostatic Discharge (ESD)
25.0
A
* see chapter 5.6 for restrictions