GARO LS4 Compact Installation Manual Download Page 7

FORM FOR ANNUAL SERVICE AND MAINTENENCE

Check point for annual service and maintenence:

Status/Value

Comment/remark

Visual check outside cabinet
LED indication lit
Check cables, connectors, connector pins
Check sockets
Check color, foil and instructions
Check external antenna (when installed)
Check fastening/fixing to ground/wall
Cean LS4 outside surface
Check locking mechanism
Check both RCCB by pressing “T” button. Check that LED 
indication switches to red color for both sides
Function test by GARO test-equipment or similar
Check that electrical power is delivered by indications on test 
equipment
Check RFID reader (when available). Indication by 2 or 3 
flashes from LED:s
Check Type 2 socket locking function (Type 2 socket versions)

Turn off the electrical power

Check gaskets
Check torque for mains terminals
Check torque for LS4 fixing screws towards ground/wall
Check torque for connectors on contactors, relays, 
energymeters and DC-PSU
Check connectors on CCU module
Measure the earthing resistans (Ohm) on EV sockets/cables 
with a multimeter
Clean inside when necessary

Turn on the electrical power

Check charging function on both sides

Plant ID:

Name:

Date:

7

EN

Summary of Contents for LS4 Compact

Page 1: ...GARO LS4 LS4 Compact Installation Manual EN GARO AB Box 203 SE 335 25 Gnosj Phone 46 0 370 33 28 00 info garo se garo se Manual 380144 2 0 EN...

Page 2: ...eneral Information 3 INSTALLATION 4 NORMAL USE 5 Service Maintenance 5 LED Indications 5 Technical specifications 6 Service information 6 Form for annual service and maintenence 7 Warranty Conditions...

Page 3: ...ble is not allowed to be used Do not use private power generators as a power source for charging Incorrect installation and testing of the LS4 stations could potentially damage either the vehicles bat...

Page 4: ...master Se example of ethernet wiring diagram picture 5 6 In cases with LS4 stations connected in a grid installation of the LS4 stations need to follow the installation order in the attached Master sl...

Page 5: ...EV s instructions After charging Release the charging cable from your EV and place the charging cable at designated place SERVICE MAINTENANCE LED INDICATIONS 3pcs green Flash Waiting for authorization...

Page 6: ...ICE INFORMATION Care and maintenance GARO charging station LS4 The warranty will only remain valid if service is performed Service is performed once a year and must be documented General authorization...

Page 7: ...tion test by GARO test equipment or similar Check that electrical power is delivered by indications on test equipment Check RFID reader when available Indication by 2 or 3 flashes from LED s Check Typ...

Page 8: ...l and serial number 7 Warranty does not cover damage occurred by incorrect use of equipment use of any non original spare parts lack of maintenance or faults caused by disassembly of the product or un...

Page 9: ...FORM GARANTIFORMUL R LS4 Model M no Electrical installation data Group fuse A Supply cable dimension Function Test Testbox EV model Date Sign Installer Company Name Owner Customer Name Installation ad...

Page 10: ...CU AL picture 1 picture 2 10 EN...

Page 11: ...picture 3 picture 4 11 EN...

Page 12: ...with TP CAT6 cable to router switch 5pcs LS4 connected with TP CAT6 cable to router switch picture 5 picture 6 Example of DLM meter installation Modbus address 2 9600 8 1 no parity Terminals 200 A 201...

Page 13: ...Fuse Left Outlet FC2 Fuse Right Outlet QA1 Contactor Left Outlet QA2 Contactor Right Outlet XN1 N Neutral terminal XPE1 PE Terminal Protection Earth T1 Powersupply DC CC1 Charge Controller Master CC2...

Page 14: ...GARO AB Box 203 SE 335 25 Gnosj Phone 46 0 370 33 28 00 info garo se garo se EN...

Reviews: