9
EN
Indication
Meaning
Action
Solid red light
RCBO has tripped or EV earth
check error is detected.
Reset RCBO
Solid red light for 3 sec
RFID tag not accepted
Red fast flash
DC current >6mA - charging has stopped.
Red slow flash
Modbus-problem energymeters
Contact servicepartner
Solid yellow light
Fault in charging cable
Check the charging cable
Flashing yellow light
The charging socket lock is not in the locked position
Check the charging
socket lock
Shifting red/green/yellow
DC detection hardware error.
Contact servicepartner
Flashing purple
Castra overheating, charging has stopped.
Troubleshooting
Indication
Meaning
Action
White fast flash
Search light indication
Solid blue light
RFID accepted - waiting to start charging.
Shifting blue intensity
EV charging in progress
Shifting red/blue
Software upgrade in progress.
Solid green
Charger in idle, waiting for EV to connect.
Slow green flash
EV connected, wait to start charging or EV has finish
charging.
Fast green flash
RFID reader ready to read tag