background image

1 of  5

HD-3XTL Operator Manual

US

First Pass

Second Pass

IMPORTANT SAFETY NOTES

No operator-serviceable parts inside 

unit. Maintenance to be done only by 

trained personnel.
High Voltage exists inside unit even 

when equipment is not under power.  

All trouble shooting and wiring checks 

must be performed by a qualified 

electrician or authorized plant 

personnel. 
Unplug power cord from the wall to 

disconnect power to the system. 
Disconnect main power and unplug 

unit from the wall before installing 

or removing device or servicing 

equipment.

PACE MAKER USERS

Due to stray magnetic fields, consult 

your physician before operating.

A non-shielded power cord may 

be used to connect AC power to 

the system. Use only power cords 

approved by Garner Products.
For continued protection against risk of 

fire, replace fuses with fuses of same 

types and ratings only.
Airflow is important. Do not cover 

chassis ventilation slots or block 

enclosure openings.
Check input voltage selection; if not 

compatible with wall voltage, have 

technician qualified by Garner Products 

modify wiring inside this system before 

connecting system plug to wall voltage.

CONTROLS AND INDICATORS

POWER Switch (RED) The power button switches the power on and off.
LCD display The LCD display gives status, automatic count, total count, software version, field 

strength, user instructions and fault messages.

Media Slot The HD-3XTL degausser operates automatically when media is inserted into the  

media slot.

LCD DISPLAY

DEGAUSSING INSTRUCTIONS

The following information appears on 

the LCD Display from power-up through 

one automatic degaussing cycle:

Automatic Degaussing

Step 1: Press POWER button ON

Displays manufacturer.

Displays degausser model.

Displays current firmware version.

Displays total erasing cycles. Number on left indicates 

number of times the counter reached 50,000.

Ready for media to be placed into the media slot. 

Displays counter for erase cycles completed since 

powered up.

Step 2: Insert media

Indicates media slot is open – this is normal when 

inserting media to be erased.

Door has closed and the erase cycle has started.

Successful erase. Indicates power and erasing field 

strength was verified and data has been eliminated.

Erased media will slide out.

Ready for next cycle. Inserting media starts the next 

cycle.

INITIATION

I

ntroduction

The high-speed, high-volume Garner HD-3XTL degausser 

is a conti nuous duty capacitive discharge degausser. The 

unit is designed to erase hard drives and tape cartridges 

that fit into the oversized media slot. The convenient media 

loading design accommodates many different types and 

sizes of media, without the need for adapters. 
Each erase cycle is measured and verified by internal 

diagnostics thus eliminating the possibil ity of a non-

erasure. For security purposes, if an insufficient field is 

detected, the HD-3XTL will not release the media.

Inspection

Inspect the degausser for shipping damage as soon as 

it is unpacked.  If the degausser or any accessories are 

damaged or fail to operate correctly, notify carrier and 

contact your dealer immediately

INSTALLATION

Power Plug

Plug the IEC connector attached to the supplied power cord 

into the receptacle on the back of the unit.

Location

The degausser must be placed on a flat, hard surface. 

Keep at least a 15 cm (6 inch) distance from any object 

that may interfere with the coo ling fan exhaust located on 

the backside of the degausser. 

Cooling

Forced air-cooling is used to maintain safe ope rating 

temperatures within the degausser. To ensure proper 

cooling, do not block the air-intake and maintain at least a 

15 cm (6 in.) distance from the back of the degausser to 

any obstacle.

DEGAUSSING INSTRUCTIONS FOR DLT MEDIA

Remove the plastic protective cases.  
Although the data is completely degaussed in one 

operation, a second pass rotated at 90 degrees is required 

to smooth out any magnetic fluctuation.  

Note: If the second pass is not completed, the tape 

drive may eject the tape from the tape drive and 

indicate that the tape needs cleaning. The second pass 

at 90 degrees will correct this condition. If you have 

any questions, please contact your dealer.

Summary of Contents for HD-3XTL

Page 1: ... 1425 GarnerProducts com 10620 Industrial Avenue Suite 100 Roseville CA 95678 The World Leader In Data Elimination Operator Manual HD 3XTL 4075 496A Manual Operator HD 3XTL Specifications subject to change without notice HIPAA HD 3XTL 2020 5 12 ...

Page 2: ...sert media Indicates media slot is open this is normal when inserting media to be erased Door has closed and the erase cycle has started Successful erase Indicates power and erasing field strength was verified and data has been eliminated Erased media will slide out Ready for next cycle Inserting media starts the next cycle INITIATION Introduction The high speed high volume Garner HD 3XTL degausse...

Page 3: ... its packaging with household trash US This shipment was packaged and delivered to the carrier with utmost care to ensure safe delivery of goods to you our valued customer PLEASE RETAIN ALL SHIPPING MATERIALS FOR FUTURE USE In the event that you need to transport the unit to a different location or to the factory for repair service you must package it for safe delivery Failure to do so may result ...

Page 4: ...3 of 5 HD 3XTL Operator Manual ...

Page 5: ...F ALL OTHER WARRANTIES REMEDIES AND CONDITIONS WHETHER ORAL WRITTEN STATUTORY EXPRESS OR IMPLIED GARNER DISCLAIMS ALL STATUTORY AND IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND WARRANTIES AGAINST HIDDEN OR LATENT DEFECTS TO THE EXTENT PERMITTED BY LAW IN SO FAR AS SUCH WARRANTIES CANNOT BE DISCLAIMED GARNER LIMITS THE DURATI...

Page 6: ...tact Carlos Contreras Tel 52 55 5272 9517 5434 52 998 255 6888 252 3547 Skype cha contreras Email concordmexico garner products com Singapore Datumstruct s Pte Ltd 33 Changi South Ave 2 03 00 Singapore 486445 Tel 65 6749 0206 Fax 65 6742 2827 Hours Monday Friday 9 00 am to 6 00 pm Singapore Standard Time GMT 8 hours Email datumstruct garner products com United Kingdom Varese Secure Ltd Lancaster C...

Reviews: