190-01553-00
GTR 200/200B Installation Manual
Rev. P
Page A-3
A.2 Shield Termination Technique – Method A.1 (Standard)
1. The appropriate number of Shield Block Backshells will be included in the particular LRU
connector kit.
Figure A-2 Method A.1 for Shield Termination
2. At one end of a shielded cable (item 4,
Figure A-1
) measure a distance between “Window Min” to
“Window Max” (Table A-2) and cut a window (max size 0.35”) in the jacket to expose the shield
(item 3, Figure A-2). Use caution when cutting the jacket to avoid damaging the individual braids
of the shield. When dealing with a densely populated connector with many cables, it may prove
beneficial to stagger the windows throughout the “Window Min” to “Window Max” range. If
staggering is not needed the “Ideal Window” length is recommended.
Suggested tools to accomplish the window cut:
• Coaxial Cable Stripper
• Thermal Stripper
• Sharp Razor Blade
Table A-2 Shielded Cable Preparations for Garmin Connectors
Backshell
Size
Number of
Pins Std/
HD
Float Min
(inches)
Float Max
(inches)
Ideal Float
(inches)
Window
Min
(inches)
Window
Max
(inches)
Ideal
Window
(inches)
1
9/15
1.25
2.25
1.75
2.75
5.25
4.25
2
15/26
1.5
2.5
2.0
3.0
5.5
4.5
3
25/44
1.5
2.5
2.0
3.0
5.5
4.5
4
37/62
1.5
2.5
2.0
3.0
5.5
4.5
5
50/78
1.5
2.5
2.0
3.0
5.5
4.5