![Garmin GPSMAP 500 Series Installation Manual Download Page 6](http://html1.mh-extra.com/html/garmin/gpsmap-500-series/gpsmap-500-series_installation-manual_564878006.webp)
Page 1-2
500 SERIES INSTALLATION MANUAL
Page Rev. B
P/N 190-00181-02
1.3.2 General Specifications
Operating Temperature Range
-20
°
C to +55
°
C. For more details see Environmental
Qualification Form
Humidity
95% non-condensing
Altitude Range
-1,500 ft to 50,000 ft
Input Voltage Range (GPS 500)
11 to 33 V
DC
Input Voltage Range (520/530)
22 to 33 V
DC
Power Requirements—P5001
(GPS 500 Main Connector)
TBD A @ 27.5 V
DC
;
TBD A @ 13.75 V
DC
Power Requirements—P5001
(GNC 520 Main Connector)
TBD A @ 27.5 V
DC
(maximum)
Power Requirements—P5001
(GNS 530 Main Connector)
1.8 A @ 27.5 V
DC
(maximum)
Power Requirements—P5002
(520/530 COM Connector)
10 mA @ 27.5 V
DC
(not transmitting);
3.0 A @ 27.5 V
DC
(transmitting)
Superflag Power Requirements
500 mA max. per superflag output @ 27.5 V
DC
1.0 A max. @ 27.5 V
DC
on P5001 (Main Superflags)
1.0 A max. @ 27.5 V
DC
on P5006 (VOR/LOC, G/S Superflags)
Software
RTCA DO-178B level C
Environmental Testing
RTCA DO-160C.
For more details see Environmental Qualification Forms
1.3.3 GPS Specifications
Regulatory Compliance
TSO C129a, RTCA DO-208
Acquisition Time
a) Search-the-Sky (without almanac, without initial position
or time): 5 minutes
b) AutoLocate™ (with almanac, without initial position or
time): 5 minutes
c) Cold Start (position known to 300 nm, time known to 10
minutes, with valid almanac): 45 seconds
d) Warm Start (position known to 10 nm, time known to 10
minutes, with valid almanac and ephemeris): 15 seconds
Max Velocity
1000 kts.
Dynamics
6 g