![Garmin GPSMAP 500 Series Installation Manual Download Page 43](http://html1.mh-extra.com/html/garmin/gpsmap-500-series/gpsmap-500-series_installation-manual_564878043.webp)
Page 4-16
500 SERIES INSTALLATION MANUAL
Page Rev. B
P/N 190-00181-02
4.8 VOR/ILS INDICATOR (GNS 530 ONLY)
4.8.1
VOR/ILS Indicator Function
NOTE
Because the GNS 530 includes a “CDI” button that performs switching between GPS and VOR/ILS on a
remote indicator, it is seldom necessary to use these outputs to drive an indicator. It is only necessary when
it is desired for a separate indicator to display VOR/ILS deviation full-time (regardless of the “CDI” button
status).
The VOR/ILS indicator displays both lateral and vertical, To/From indications, lateral and vertical flags and
superflags. GNS 530 connector 5006 always outputs the VOR/Localizer/Glideslope navigation
information. The VOR/ILS pins on GNS 530 connector 5006 are used to drive an indicator that displays
VOR/ILS information at all times, regardless of the CDI selection on the GNS 530.
VOR/LOC COMPOSITE OUT is a standard VOR/Localizer Composite output signal which may be used to
drive the Left/Right, TO/FROM, and Flag indications of certain navigation indicators that contain an
internal converter.
The ILS ENERGIZE output will go low when the VLOC frequency is channeled to a localizer channel.
4.8.2
VOR/ILS Indicator Electrical Characteristics
4.8.2.1 Superflags
Pin Name
Connector
Pin
I/O
VOR/LOC SUPERFLAG
P5006
15
Out
GLIDESLOPE SUPERFLAG
P5006
38
Out
The output supplies not less than 500 mA on a 28 volt system and 250 mA on a 14 volt system with the
output voltage not less than (AIRCRAFT POWER - 3 V
DC
) when the flag is to be OUT OF VIEW. The
output voltage with respect to ground is less than 3 V
DC
when the flag is to be IN VIEW.
4.8.2.2 Deviation
Pin Name
Connector
Pin
I/O
VOR/LOC +LEFT
P5006
5
Out
VOR/LOC +RIGHT (VOR/LOC COMMON)
P5006
6
Out
GLIDUP
P5006
32
Out
GLIDDOWN/-FLAG (GLIDESLOPE
COMMON)
P5006
31
Out
The deviation outputs are each capable of driving up to three 1000
Ω
meter loads with
±
150 mV
DC
±
10%
with respect to 2.5V Common for full-scale deflection. The drive circuit provides for more than full-scale
deflection with a maximum course deviation output voltage of ± 300 mV
DC
±
10%.
4.8.2.3 TO/FROM
Pin Name
Connector
Pin
I/O
VOR/LOC +TO
P5006
1
Out
VOR/LOC +FROM (VOR/LOC COMMON)
P5006
2
Out
The output is capable of driving up to three 200
Ω
meter loads. When indicating TO, the output is
+225 ± 75 mV
DC.
When indicating FROM, output is -225 ± 75 mV
DC.
When invalid information is present
(Flag IN VIEW) the TO/FROM output is 0 ± 10 mV
DC.