4.4.1.2 RS-485/422
The GIA 63(X) contains a total of 5 channels of RS-485 serial data communications. Any two of these
channels can also be configured as one RS-422 channel to allow for system flexibility. These data busses
conform to EIA standard RS-485, or RS-422, depending on which mode they are currently operating in.
Table 4-12. RS-485/422
Pin Name
Connector
Pin
I/O
RS-485 3 A/RS-422 IN A
P603
27
I/O
RS-485 3 B/RS-422 IN B
P603
28
I/O
RS-485 5 A/RS-422 OUT A
P603
36
I/O
RS-485 5 B/RS-422 OUT B
P603
37
I/O
RS-485 1 A
P603
23
I/O
RS-485 1 B
P603
24
I/O
RS-485 2 A
P603
25
I/O
RS-485 2 B
P603
26
I/O
RS-485 4 A
P603
4
I/O
RS-485 4 A
P603
5
I/O
RS-485 4 B
P603
6
I/O
RS-485 4 B
P603
7
I/O
Summary of Contents for GIA 63
Page 1: ...190 00303 05 December 2012 Revision Y GIA 63 Installation Manual ...
Page 10: ...GIA 63 Installation Manual 190 00303 05 Page viii Rev Y This page intentionally left blank ...
Page 58: ...GIA 63 Installation Manual 190 00303 05 Page 1 48 Rev Y This page intentionally left blank ...
Page 74: ...GIA 63 Installation Manual 190 00303 05 Page 2 16 Rev Y Figure 2 4 GIA 63H Standalone Rack ...
Page 76: ...GIA 63 Installation Manual 190 00303 05 Page 2 18 Rev Y This page intentionally left blank ...
Page 84: ...GIA 63 Installation Manual 190 00303 05 Page 3 8 Rev Y This page intentionally left blank ...
Page 124: ...GIA 63 Installation Manual 190 00303 05 Page 4 40 Rev Y This page intentionally left blank ...
Page 128: ...GIA 63 Installation Manual 190 00303 05 Page A 4 Rev Y This page intentionally left blank ...