__________________________________________________________________
Page 7-50
Cirrus Perspective™ Line Maintenance Manual
Rev. E
190-00920-00
12.
In
the
FILE
box,
turn
the
small
FMS
knob
to
show
the
list
of
File
choices,
you
will
need
to
load
any
of
the
following
Files
if
the
aircraft
is
equipped
with
the
following
optional
equipment
:
a.
Oxygen
‐
GEA
Configuration
file
b.
Ice
Protection
(NH
and
FIKI)
–
GEA
Configuration
file
c.
SR22
(only)
Oil
Temperature
Sensors
(2)
–
GEA
Configuration
file
13.
Turn
off
the
system.
7.6.2
GEA
Testing
The
following
tests
are
recommended
if
the
unit
is
removed
or
replaced.
1.
Each
GEA
71
sensor
input
must
be
checked
with
the
aircraft
engine
off.
Make
sure
all
engine
information
systems
are
valid
on
the
MFD,
and
that
no
GEA
71
related
alerts
appear
on
the
PFD.
Exercise
and
test
all
discrete,
analog,
and/or
digital
inputs
and
check
for
appropriate
responses.
2.
With
the
STBY
BATT
CB
pulled,
check
to
see
that
the
STBY
BATT
S
current
from
the
bottom
right
corner
of
the
EIS
strip
on
the
MFD
is
indicating
0.0
amps.
No
other
maintenance
is
required
when
the
indication
is
0.0.
If
the
STBY
BATT
current
is
indicating
anything
other
than
0.0
amps,
perform
the
GEA
71
Standby
Battery
High
‐
Side
Current
Monitor
Calibration
procedure.
Summary of Contents for Cirrus Perspective SR20