background image

Part # 4520898 (05/01/14)

Page 24

Fault

Possible Cause

Action To Take By Operator Or Operating 
Personnel

No heating
Operation indicator light 
is OFF (dark)

No mains supply

Check the electrical supply (cable plugged 
onto the wall socket)
Check preliminary fuses

Control knob is in OFF-position

Turn control knob ON

Cooker is defective

Ask your supplier for repair service
Unplug the cooker from the mains supply

No heating
Operation indicator 
light is fl ashing (If an 
error code is fl ashing see 
section “Malfunction with 
error code”)

Pan is too small (bottom diameter less than 
4.72” (120mm), only BH/IN and SH/IN)

Use a suitable pan

Pan is not placed in the center of the heating 
area (the cooker cannot detect the pan)

Move the pan to the center of the heating area

Unsuitable pan

Choose a pan recommended for induction 
cooking 1

Cooker defective

Ask your supplier for repair service, unplug the 
cooker from the mains supply

Poor heating
Operation indicator light 
is ON (shining)

Used pan is not appropriate

Use a pan recommended for induction cooking 
and compare the result with “your” pan

Air-cooling system obstructed

Verify that air inlet and air outlet are not 
obstructed with objects

Ambient temperature is too high (the cooling 
system is not able to keep the cooker in normal 
operating conditions 2)

Verify that no hot air is sucked in by the fan. 
Reduce the ambient temperature. The air inlet 
temperature must be lower than 104°F /40°C.

One phase is missing (only units with three 
phase supply)

Check preliminary fuses

Cooker defective

Ask your supplier for repair service, unplug the 
cooker from the electrical supply

No reaction to control 
knob positions

Control knob defective

Ask your supplier for repair serviced, unplug 
the cooker from the mains supply

Heating cycle switches off  
and on 
Within minutes, fan is 
active

Air inlet or outlet obstructed or fan dirty

Remove objects from air inlet and air outlet 
slots, clean the slots
Clean fan

Heating cycle switches off  
and on 
Within minutes, fan is 
never active

Fan defective
Fan control defective

Ask your supplier for repair service

To verify, if the pan is suitable, use a permanent magnet and fi nd out if it sticks on the bottom of the pan. If not, your pan 
is not suitable for induction cooking. Choose a pan which is recommended for induction cooking. Choose pan material 
suitable for induction appliances.

The cooling-system (fan) starts to operate when the ambient temperature in the control area exceeds 131°F/55°C. At 
heat temperatures higher than 158°F /70°C the controller automatically reduces the power to keep the unit in normal 
operating conditions. The cooker runs in a non continuous mode. This mode can be heard.

TROUBLESHOOTING continued

Malfunction Without Error Code

Summary of Contents for SH/IN 5000

Page 1: ...MMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE IN...

Page 2: ...Part 4520898 05 01 14 Page 2...

Page 3: ...ngerous voltage CAUTION Indicates a hazard or unsafe practice which could result in minor personal injury or property damage Electromagnetic field IMPORTANT INFORMATION Warning Risk of fire or electri...

Page 4: ...Part 4520898 05 01 14 Page 4...

Page 5: ...IN 8000 11 Unit Placement 12 Installation of Operating Unit 12 Fresh Air Intake Installation 13 Instructions For Assembly Induction Built In Units 14 Guidelines For Assembly 14 Mounting Instructions 1...

Page 6: ...ximum Relative Humidity Of Air Storage 10 90 Function 30 90 ELECTRICAL SPECIFICATIONS MODEL VOLTAGE Total KW BH IN2500 208 230 240 2 5 SH IN 3500 208 230 240 3 5 SH IN 5000 208 230 400 440 5 0 SH WO I...

Page 7: ...tures Simple operation with rotary switch with integrated mains switch Compact module in a frame design with an induction generator controller coil ventilator glass ceramic cooking zone with power rot...

Page 8: ...fresh air by fixing an air duct including shackle or by air openings The air exit must not to be hindered by any obstructions Electrical Supply Please observe the following rules 1 Check and ensure t...

Page 9: ...73mm Side View of the right 0 06 1 5mm air exit air exit 4 06 103mm Ventilator Mains Cable air supply 6 73 171mm 11 02 280mm Ceran surface 10 23 260mm 10 23 260mm 12 20 310mm 12 20 310mm Front view Co...

Page 10: ...age 10 INSTALLATION continued Cut Out for Models SH IN 3500 And SH IN 5000 The size of the cut out in the built in area must be 13 78 x 13 78 350 x 350mm the depth 9 45 240mm and the base at least 16...

Page 11: ...ALLATION continued Cut Out For Models SH WO IN 3500 SH WO IN 5000 And SH WO IN 8000 The size of the cut out for the built in area must be 14 37 x 14 37 365 x 365mm the depth 11 81 300mm and the base a...

Page 12: ...it In order to fix this unit on the surface of the enclosure a cut out for the power switch and the LED must considered The operator control panel has to be fixed vertically on the installation panel...

Page 13: ...nches for dual units for the hot air to escape by installer Failure to provide adequate ventilation for the unit will result in the unit overheating nuisance shut down and potential failure of the uni...

Page 14: ...ake sure that the in coming and outgoing exhaust air do not mix We recommend guaranteeing the supply of fresh air by using a tube with screens vent ducts or Air Intake Kit It is highly recommend that...

Page 15: ...Part 4520898 05 01 14 Page 15 3...

Page 16: ...Part 4520898 05 01 14 Page 16 Figure 4...

Page 17: ...Part 4520898 05 01 14 Page 17 Figure 5...

Page 18: ...Part 4520898 05 01 14 Page 18 Figure 6...

Page 19: ...id injuries burning do not touch this area Use a pan suitable for induction cooking having a bottom diameter of at least 4 72 120mm only BH IN and SH IN 1 Put some water in the pan and place it in the...

Page 20: ...stored Out Of Operation If the cooker is not in use make sure that the control knob is in the OFF position If you don t use the cooker for a long period several days unplug the unit Make sure that no...

Page 21: ...sconnected from the electric connection Don t touch any parts inside the cooker If the supply cord is damaged it must be replaced by the manufacturer the service agent or a similarly qualified person...

Page 22: ...identical to other similar surfaces like glass Do not use corrosive or abrasive cleaning agents such as grill and oven sprays stain and rust removers scouring powder and rough sponges 2 Before being...

Page 23: ...ir inlet temperature must be lower than 104 F 40 C E07 Empty cooking sensing element activated Reset empty cooking protection by switching the unit off E08 Ambient temperature beyond operating range M...

Page 24: ...normal operating conditions 2 Verify that no hot air is sucked in by the fan Reduce the ambient temperature The air inlet temperature must be lower than 104 F 40 C One phase is missing only units with...

Page 25: ...r supplier for repair service 1 To verify if the pan is suitable use a permanent magnet and find out if it sticks on the bottom of the pan If not your pan is not suitable for induction cooking Choose...

Page 26: ...Part 4520898 05 01 14 Page 26...

Page 27: ...Part 4520898 05 01 14 Page 27...

Page 28: ......

Reviews: