Installation Instructions for
Rayburn 200SFW and Rayburn
212SFW Solid Fuel Cooker
PERFORMANCE
1
02/15 EINS 514406
Consumer Protection
As responsible manufacturers we take care to make sure that our
products are designed and constructed to meet the required safety
standard when properly installed and used.
IMPORTANT NOTICE: PLEASE READ THE ACCOMPANYING
WARRANTY.
Any alteration that is not approved by AGA could
invalidate the approval of the appliance, operation of the warranty
and could affect your statutory rights.
All local regulations including those referring to National and
European standards need to be complied with when installing
the appliance.
Important
This appliance may contain some of the materials that are
indicated. It is the Users/Installers responsibility to ensure that the
necessary personal protective clothing is worn when handling,
where applicable, the pertinent parts that contain any of the listed
materials that could be interpreted as being injurious to health and
safety, see below for information.
Firebricks, Fuel beds, Artificial Fuels
- when handling use
disposable gloves.
Fire Cement
- when handling use disposable gloves.
Glues and Sealants
- exercise caution - if these are still in liquid
form use face mask and disposable gloves.
Glass Yarn, Mineral Wool, Insulation Pads, Kerosene/Gas Oil
-
may be harmful if inhaled, may be irritating to skin, eyes, nose and
throat. When handling avoid inhaling and contact with skin or
eyes. Use disposable gloves, face-masks and eye protection.
After handling wash hands and other exposed parts. When
disposing of the product, reduce dust with water spray, ensure that
parts are securely wrapped.
WARNING
THE ASHPIT DOOR AND FIREBOX DOORS MUST
BE LOCKED CLOSED AT ALL TIMES DURING
NORMAL USE, EXCEPT WHEN LIGHTING OR RE-
FUELLING
REMEMBER, when replacing a part on this
appliance, use only spare parts that you can be
assured conform to the safety and performance
specification that we require. Do not use
reconditioned or copy parts that have not been
authorised by AGA.
The Rayburn 200SFW is intended to be used for
cooking only. The Rayburn 212SFW is intended to
supply heating for cooking and domestic hot water.
The Rayburn 200SFW has been tested using Ancit and
wood logs. The nominal heat output of this appliance is
Ancit 7.1 kW and wood logs 5.8 kW.
The Rayburn 212SFW has been tested using Ancit and
wood logs. The nominal heat output of this appliance is
Ancit 6.8 kW and wood logs 6.5 kW.
Ancit provides about 2.6 kW to hot water and 4.3 kW to
the appliance. Wood provides about 2.0 kW to hot
water and 4.5 kW to the appliance. Other fuels may
give a slightly different result.
Weight of Rayburn 212SFW - 300 Kgs.
Weight of Rayburn 200SFW - 240 Kgs.
There is no requirement for an electrical power supply.
Flue gas mass flow g/s 5.3.
The mean flue gas temperature of the Rayburn
200SFW directly downstream of the flue spigot at
nominal heat output is 200ºC.
The mean flue gas temperature of the Rayburn
212SFW directly downstream of the flue spigot at
nominal heat output is 203ºC.
The cooker fully meets the requirements of BS EN
12815 : 2001 and A1: 2004 and is fully approved by the
HETAS Ltd Approval Scheme.
Air for combustion within the firebox and the rate of
burning is determined by the manually operated
spinwheel control on the ashpit door and flue damper.
With normal usage in 24 hours continuous burning the
Rayburn 212SFW has an approximate output of 100
gallons of hot water. To provide 2 or 3 hot baths at
intervals and normal household requirements, the
following conditions must be fulfilled:-
FUEL
ANCIT
WOOD
ANCIT
WOOD
FLUE GAS MASS FLOW
MODEL
200
200
212
212
5.3 g/s
5.6 g/s
5.9 g/s
5.9 g/s
MEAN FLUE
GAS TEMP.
199°C
196°C
203°C
207°C