9. Troubleshooting
PROBLEM
SOLUTION
Heat alarm does not
sound when tested.
NOTE:
Push and hold
test button for at least
five (5) seconds while
testing!
1.
Check that AC power is turned on.
2.
Turn off power. Remove heat alarm
from mounting plate and:
a.
check that connector plug is securely
attached.
b.
Check that Section 10 Battery is
installed correctly.
3.
Clean heat alarm.
Heat alarm beeps about
once every 40 seconds
Turn off AC power, replace battery and
Clean alarm. See
“Section 10 Battery
Replacement”
and
“Section 11 Cleaning
Your Alarm”
Heat alarm sounds
unwanted alarms.
1.
Hire an electrician to move heat alarm
to a new location.
See
“Section 3 Installation Instructions”
and
“Section 4 Locations to Avoid
”
Interconnected heat
alarms do not sound
when system is tested.
1.
Press and hold button for at least five
(5) seconds after the first unit sounds.
2.
Turn off AC power or circuit breaker
and check the interconnect wiring.
See
“Section 5 Wiring instructions”
.
3 chirps every
40 seconds
1.
Before 10 years of operation: unit is in
fault mode. Contact customer service.
2.
After 10 years of operation: end of
life warning. Alarm must be replaced
(REPLACE IMMEDIATELY!)
NOTE:
Visit our website: www.garlandcables.com.au, if your alarm
does not seem to operate correctly.