background image

Part # 1382684 (01/08)

Page 8

OPERATION

NOTE: Ensure the gas supply to the appliance is turned “ON” . 

During the initial ignition cycle, air must be purged from the 

gas line and thus it may take one to two minutes for the pilot 

burner to ignite . 

M,MS Models

Pilot Lighting Instructions

1 .  The in-line service shut-off valve should be in the “ON” 

position .

2 .  With a lighted taper light the pilots which are located at 

the rear of the main burner .

3 .  The pilot flame should be approximately 7/8”  

(22 mm) long for proper ignition of the burners . The 

pilot adjustment valve is located by sliding the drip 

tray forward . The adjustment valves are located on the 

manifold pipe, which runs horizontally across the back of 

the unit, behind the drip tray, one is at the left rear and 

the other is at the right rear . 

4 .  To adjust the pilot light, turn the brass screw counter-

clockwise to increase the pilot flame, and clockwise to 

decrease the flame . 

NOTE: No more than 7/8” (22 mm) pilot flame length should 

be required . Too high a setting will cause the flame to lift off 

or will create excessive carboning . Do not adjust the pilot 

flame lower than 7/8” (22mm) long because this can cause 

delayed ignition at the burner . The delayed ignition could 

cause the burner tiles to crack, in that case the burner would 

have to be replaced .

Main Burner Operation

1 .  Turn the main burner to the “MAX” position .

2 .  Immediately check ignition of the burner . 

CAUTION:  Should ignition fail after five (5) seconds, turn the 

valve off and wait five (5) minutes before trying again . The 

pilot gas is not interrupted automatically, it is the responsibility 

of the operator to check the ignition of the burners 

immediately after the burner valve has been turned on . 

Shut Down

1 .  Turn all valves to the “OFF” position by rotating the knob 

clockwise 1/4 turn .

2 .  If the unit is to be shut down for an extended period of 

time close the inline gas valve . 

MST Models

Operating Controls

OFF

IGNITION

MAX

MIN

Lighting Instructions

1 .  Push in the tap and turn it counter-clockwise to the 

Ignition Position “ ”

2 .  Holding the tap fully in, light the pilot with a match or 

taper . 

Summary of Contents for MSR16

Page 1: ...Ontario L4W 1X4 CANADA Phone 905 624 0260 Fax 905 624 5669 Enodis UK LTD Swallowfield Way Hayes Middlesex UB3 1DQ ENGLAND Telephone 081 561 0433 Fax 081 848 0041 Part 1382684 01 08 2005 Garland Commer...

Page 2: ...expose you to airborne particles of glass wool ceramic fibers Inhalation of airborne particles of glass wool ceramic fibers is known to the state of California to cause cancer Operation of this produ...

Page 3: ...ry Regulations 6 Gas Supply 7 Ventilation and Air Supply 7 Testing And Adjustments 7 OPERATION 8 M MS Models 8 Pilot Lighting Instructions 8 Main Burner Operation 8 Shut Down 8 MST Models 8 Operating...

Page 4: ...Natural 6 WC 15mbar Propane 11 WC 28mbar For instillations in non combustible locations only NOTE Data applies only to North America Gas input ratings shown here are for installations up to 2 000 ft...

Page 5: ...re and maintenance Periodic inspections by your dealer or a qualified service company are recommended to check temperatures burner adjustments and ensure moving parts are operative Wherever possible a...

Page 6: ...salamander with sheet metal screws previously removed Wall Mounted Salamanders 1 Each gas appliance must be located with respect to building construction and other equipment so as to permit access to...

Page 7: ...stem to work properly replacement air must enter the room in which the vent is located The amount of air that is exhausted must equal the amount entering make up air INSTALLATION continued All gas bur...

Page 8: ...m pilot flame length should be required Too high a setting will cause the flame to lift off or will create excessive carboning Do not adjust the pilot flame lower than 7 8 22mm long because this can c...

Page 9: ...e point where the burner rods no longer glow and the flame travels back and forth on the face of the ceramics OPERATION continued This adjustment has been factory pre set however with changing pressur...

Page 10: ...otice that the valves are becoming harder to turn it is then time to have them greased We suggest an authorized service agent who is familiar with the appliance and working with natural and propane ga...

Page 11: ...depending on the installation Servicing must be carried out by competent persons in accordance with the law SAFETY It is essential that the instructions in this booklet are strictly followed for the...

Page 12: ......