![Garland Moisture+ MPOE5L Installation And Operating Instructions Manual Download Page 13](http://html1.mh-extra.com/html/garland/moisture-mpoe5l/moisture-mpoe5l_installation-and-operating-instructions-manual_3756968013.webp)
Part # 4518084 Rev. 1 (09/04)
Page 13
Temperature does not correspond to the pyrometer,
enter the value on the pyrometer using buttons 1
– 0. The value will be input as Set Temp.
3. Press “ENTER” (lower right blank) to accept the
changes. The Actual Temperature will change to
equal the value input for Set Temperature. Press
Cancel to exit Temperature Calibration.
• After the desired Tests are complete, press
“CANCEL” to exit Diagnostics Mode.
Control Safety Features
The control has several built in safety features to protect
both the user and the oven itself.
• If the actual temperature inside the oven exceeds
the set temperature by 50°F, the display will show
“HI TEMP” and the alarm will sound. The fan will
continue to run, however,
power to the heaters will
be cut.
• If the actual temperature sensed inside the oven
exceeds 575°F, the control will change to “HELP”
and the alarm will sound continuously. All control
operations will shut down except the alarm.
• NOTE
:
The control will need a complete power
down and restart (unplug/plug in oven) before
any control functions will become operational. If
the problem persists, contact a service technician.
OPERATING INSTRUCTIONS continued...
• In the event of a temperature probe failure, the
control will become inoperative and the display
will show “PROBE ERROR”. Once the problem
is corrected, the control must be cycled On/Off
(using the ON/OFF button) in order to become
operative again.
Installing a New Pecipe Program
Using the CARD Reader
1. Remove the two screws securing the controller
button pad to the front panel using a Phillips head
screw driver, and drop the button pad to access the
CARD reader.
2. Press and hold the programming
button (bottom right button), until the
controller display reads “enter code”.
3. Insert the CARD into the reader with
gold side up.
4. The LED on the reader will illuminate
yellow for five seconds then red during the coding.
5. When the LED changes color to green, remove the
card.
6. Program is complete. Close the panel and exit the
program mode by hitting the cancel button.
7. Power down the oven and re-start.
Summary of Contents for Moisture+ MPOE5L
Page 2: ...Part 4518084 Rev 1 09 04 Page 2...
Page 16: ......