background image

Part # 4518084 Rev. 1 (09/04)

Page 11

OPERATING INSTRUCTIONS continued...

Diagnostics Mode

•  To  enter  Diagnostics  Mode,  press  and  hold  the 

Program (lower right blank) button for three, (3), 

seconds. When prompted, enter the code: 

3-4-2-

4

 using the buttons 1 – 0. Press “ENTER” (lower 

right blank).

 
•  After entering the code and pressing “ENTER,” the 

Moisture Plus Part Number will be displayed briefly 

and  then  the  display  will  change  to  Diagnostics 

Test – Buttonpad Test. Use the “YES” (upper right 

blank) and “NO” (Preheat Bread 425) buttons to 

scroll through the available diagnostic tests. Press 

“ENTER” to begin the desired test. 

 

  Buttonpad Test

 

1.  The display will show “Press the On/Off Button”. 

Upon pressing the On/Off button, the LED for the 

ON/OFF button will light briefly and then go out 

to show that the button works.

 
2.  The  display  will  then  prompt  the  user  to  press 

the  “TEMP”  button  (upper  right  blank).  After 

the user presses the “TEMP” (upper right blank) 

button, the corresponding LED will light to show 

the button works. The control will then continue 

to prompt the user to press the remaining control 

buttons. If the LED of the button pressed does not 

light, a buttonpad problem exists. After completing 

the Buttonpad Test, you will return to Diagnostics 

Mode. (Press “CANCEL” at any time during the 

test to return to Diagnostics Mode.)

  Door Switch Test

 
1.  After selecting Door Switch Test and pressing the 

“ENTER” (lower right blank) button, the display 

will show the position of each of the two switches. 

Open  and  close  the  door  slowly  to  verify  the 

operation of the door switches.

 

  Proper Door Switch Activation:

•  Starting  with  the  door  closed,  the  switches 

should read:

•  Slowly begin to open the door. Door switch 1 

should be the first to change states:

•  Next, door switch 2 should change state to:

•  If the switches do not operate as stated above, 

there is a problem with the door switches.

•  Press “CANCEL” to exit the Door Switch Test 

and return to Diagnostic Mode.

Summary of Contents for Moisture+ MPOE5L

Page 1: ...t has been improperly installed adjusted operated or not maintained in accordance with national and local codes or installation instructions provided with the product or any product that has its seria...

Page 2: ...Part 4518084 Rev 1 09 04 Page 2...

Page 3: ...ntrol Operation 8 Startup and Normal Operation 8 During the Cooking Cycle 8 Shutdown Auto Cool Down 8 Control Programming 9 Recipe Programming 9 System Programming 10 Diagnostics Mode 11 Buttonpad Tes...

Page 4: ...ed base or shelf Each oven deck requires a separate electrical connection Garland recommends a separate 30 amp circuit be provided for each oven Customer must provide a 1 4 NPT water connection capabl...

Page 5: ...NPTF tting at the rear of the oven The ability to move the oven for service and cleaning may be a consideration when choosing the type of connection and supply line to be attached at this tting The mo...

Page 6: ...nds will toggle the control between F and C or C and F The control will beep three 3 times when the temperature units have changed 3 In Programming this Blank Button functions as the YES button and is...

Page 7: ...items Preheat Bakery 325 325 F high fan speed Preheat Bakery 350 350 F high fan speed Preheat Bread 425 425 F high fan speed NOTE Preheat Bread has additional functions 1 In Programming Preheat Bread...

Page 8: ...of the product that will be done rst will be displayed and the corresponding LED will ash rapidly The LED s of the other products cooking will ash slowly 4 The external display will show the count do...

Page 9: ...ENTER lower right blank 4 The display will then prompt for the Cook Temperature Enter the temperature using buttons 1 0 and press the ENTER lower right blank button 5 Next the display will prompt for...

Page 10: ...s counting down 1 To enter System Programming press and hold the Program lower right blank button for three 3 seconds When prompted enter the code 4 2 7 6 using the buttons 1 0 Press ENTER lower right...

Page 11: ...right blank After the user presses the TEMP upper right blank button the corresponding LED will light to show the button works The control will then continue to prompt the user to press the remaining...

Page 12: ...he test will complete Press CANCEL to return to Diagnostics Mode Moisture Test 1 After selecting Moisture Test and pressing ENTER the control will show the moisture status as OFF for ten seconds 2 The...

Page 13: ...ept the alarm NOTE The control will need a complete power down and restart unplug plug in oven before any control functions will become operational If the problem persists contact a service technician...

Page 14: ...wed to cool su ciently before beginning the cleaning procedure 2 Wipe exposed cleanable surfaces when cool with a mild detergent and hot water Stubborn residue spots may be removed with a lightweight...

Page 15: ...to its storage compartment Motor Care The motor in this convection oven is maintenance free since it is constructed with self lubricating sealed ball bearings It is designed to provide durable servic...

Page 16: ......

Reviews: