Installation
RTCSmp Built-In Temperature Controlled Hold-Line
10
Part # 4532286 Rev 3 (6/10/14)
(
H
)
IMPORTANT
Minimum clearance for heat plate under counter surface: 100mm / 3.94”
(
I
)
Cable for operation unit connecting to the induction generator, MAX 300cm / 118”.
(
J
) Cables for coil and sensors.
IMPORTANT
Always route sensor and communication cables separately and away from the coil cables.
4.4
Configurations
One Induction Generator can power up to four (4) Heat Retaining Plates. You need to install two (2) control units
for any configurations with 2 to 4 Heat Retaining Plates.
Model
Configuration
(Heat Retaining Plate(s), Control Switch(s), and Induction Generator are shown)
HO IN 450
One switch controls one heat retaining plate.
One (1) heat retaining plate, one (1) generator and one (1)
control unit.
HO IN 900
Two switches; each controls only one heat retaining plate.
Two (2) heat retaining plate, one (1) generator and two (2)
control units.
HO IN 1350
Two switches; one switch controls one heat retaining plate and
the other switch controls two plates.
Three (3) heat retaining plate, one (1) generator and two (2)
control units.
HO IN 1800
Two switches; each controls two heat retaining plates.
Four (4) heat retaining plate, one (1) generator and two (2)
control units.