Additional Errors
Problem
Possible Cause
Measure
Code No.
No
No
W
No
Operation lamp is continuously “ON”
S20
Cooking platform does not
heat enough
U10
Non induction type pan
M10
Compare on another
cooking platform and with
an induction type pan
E
U200
1 phase is missing
M200
Check mains cable
connection
L
U12
Power board defective
M12
Replace power circuit
board
L
U14
CPU-circuit board
defective
M14
Replace CPU-circuit board
L
S21
Cooking platform
continuously on
maximum power
U50
Operational control
defective
M50
Check operational control
L
U14
CPU-circuit board
defective
M14
Replace CPU-circuit board
L
U12
Power circuit board
defective
M12
Replace power circuit
board
L
S22
Empty cooking platform
switches “on“
U220
Pan detection defective
M220 Check pan detection
L
S23
Little metallic objects are
heated on the cooking
platform
U220
Pan detection defective
M220 Check pan detection
L
No.
Operation lamp fl ashes
S24
Cooking platform does not
heat at all
U240
Pan too small (Diameter
less than 12cm, 4.75”)
M240 Use appropriate pan
E
U200
1 phase is missing
M200
Check connection of
mains cable
L
U220
Pan detection defective
M220 Check pan detection
L
U241
Short circuit on generator
M241
Replace or repair
generator
L