Problem
Possible Cause
Measure
Code No.
No
No
W
No.
Operation lamp and error lamp “OFF”
S25
Unit does not heat, no
reaction, contactor does
not work
U250
Building’s power fuses
defective, error on
electrical transmission
M201 Check mains supply
L
U251
Error on operational
control
M251 Check operational control
L
S26
Building fuses blow when
unit is switched on
U241
Short circuit in generator
M241
Repair or replace
generator
L
S27
Some cooking platforms
do not heat
U271
Generator defective
M241
Repair or replace
generator
L
S28
Unit does not heat, no
reaction, no contactor
U13
Error on DIP-Switch-
adjustment on CPU
M13
Check DIP-Switch
adjustment
L
Legend: W = Who should complete “Measure” E = End user L = Supplier
Repair Of Problems
Measure
Activity
Comment
M10
•
Compare on another cooking platform and with an induction
type pan
Check if the pan is appropriate to
induction cooking or not: use a
magnet.
M11
•
Check connection of coil
•
Check coil on line break
•
Coil overheated (brown color change)
M12
•
Change power circuit board
M13
•
Check DIP-Switch adjustment on CPU-circuit board
M14
•
Replace CPU-circuit board
M30
•
Clear ventilation system
M31
• Clean
fan
M32
•
Connect fan directly at 230V
M33
• Change
rectifi er circuit board
M34
•
Measure heat-sink temperature sensor resistor
At 25º Celsius (77ºF) resistor will read 20kOhm
At 70º Celsius (158ºF) resistor will read 3,5kOhm
•
Check short circuit to case
•
For a test: short-out the sensor with a 20kOhm fi xed resistor
Disconnect temperature sensor
M40
• Switch
off unit, cool down and switch on again. Use a pan with
cold water
Switch off fi eld!