Part Number 4532879 1/15
Installation
Section 2
ISTALLATIO CLEARACE
DAGER
Risk of fire/shock/equipment failure. All minimum
clearances must be maintained. Do not obstruct vents
or openings.
Installation Clearance – Components
b
c
a
a
d
d
b
b
a
Cable Bend /
Connection
Clearance
(minimum)
b
Air Vents
Clearance
(minimum)
c
Clearance
(minimum)
d
Clearance
(minimum)
Compact Line
Induction
Module
73mm / 2.88”
30mm / 1.18”
200mm / 7.88”
(measured from
below glass;
glass shown)
40±1mm /
1.58±0.005”
(from below
glass to
underside of
coil carrier,
glass shown)
Operation Unit
63.5mm / 2.5“
-
-
-
Installation Clearance – Quad Models
The gap required between two dual compact units is restricted by the glass size. This gap can be measured from center to
center of coils, or simply from edge of one unit to the next as shown in the illustration.
y
y
y
y
Unit Length
Glass Size
Distance “y”
555mm
600 x 600mm
(23.62” x 23.62”)
320mm
(12.60”)
610mm
650 x 650mm
(25.60” x 25.60”)
320mm
(12.60”)
655mm
720 x 720
(28.35” x 28.35”)
360mm
(14.17”)